FDA UDI
In Commercial Distribution
🇺🇸 United States
Advantage
DI: 00801741077227
·
Model: 5600200
·
Davol Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Advantage
- Primary DI
- 00801741077227
- Version / Model
- 5600200
- Catalog Number
- 5600200
- Company Name
- Davol Inc.
- Labeler DUNS
- 001191048
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-04-29
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- d0f72952-ac7d-4d87-8de5-3f013ac053d0
Device Description
Davol Advantage Reusable Quick-Disconnect Needle Tip Electrosurgical Attachment, 5mmx33cm
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| GEI | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES | General, Plastic Surgery | 878.4400 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62061 | Endoscopic electrosurgical electrode, monopolar, reusable | An invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece/housing and has no electrical or mechanical controls (e.g., does not include controlling ring-handles); it is not intended for gas-enhanced electrosurgery. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00801741077227 | GS1 |
Customer Contacts
- Phone
- +1(800)562-0027
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K003674 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 33 | Centimeter | |
| Outer Diameter | 5 | Millimeter |