FDA UDI
In Commercial Distribution
🇺🇸 United States
Safety Excalibur Introducer System with Punctur-Guard
DI: 00801741074776
·
Model: 4033413
·
Bard Access Systems, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Safety Excalibur Introducer System with Punctur-Guard
- Primary DI
- 00801741074776
- Version / Model
- 4033413
- Catalog Number
- 4033413
- Company Name
- Bard Access Systems, Inc.
- Labeler DUNS
- 044611812
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-06
- Public Version
- 2
- Public Version Date
- 2018-03-29
- Public Version Status
- Update
- Public Device Record Key
- f3752c03-b275-42c5-aa12-00aa9436810d
Device Description
EXCALIBUR INTRO 3FR
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FOZ | Catheter,intravascular,therapeutic,short-term less than 30 days | General Hospital | 880.5200 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61502 | Vascular catheter introduction needle | A sterile, sharp bevel-edged, hollow tubular metal instrument designed to make the initial percutaneous puncture to access a vein and/or artery during vascular catheterization. It is available in a variety of forms to enable a catheter to be introduced directly, or a guidewire to be introduced (Seldinger technique); the therapeutic or diagnostic aspiration of fluids may be achieved during its placement. Its lumen is not intended to be filled with an obturator/dilator and it does not include additional access devices. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 10801741074773 | GS1 | CA | 5 | In Commercial Distribution | |
| Primary | 00801741074776 | GS1 |
Customer Contacts
- Phone
- +1(800)545-0890
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Needle Gauge | 19 | Gauge | |
| Length | 35 | Millimeter |