FDA UDI
In Commercial Distribution
🇺🇸 United States
Bio-Medicus™
DI: 00763000193232
·
Model: CB96345-027
·
MEDTRONIC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Bio-Medicus™
- Primary DI
- 00763000193232
- Version / Model
- CB96345-027
- Company Name
- MEDTRONIC, INC.
- Labeler DUNS
- 006261481
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2019-04-21
- Public Version
- 3
- Public Version Date
- 2023-08-07
- Public Version Status
- Update
- Public Device Record Key
- 798b0c7b-3e8a-4659-9756-95032a94d8cf
Device Description
CANN CB96345-027 BIO-MED 27FR
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DWF | Catheter, cannula and tubing, vascular, cardiopulmonary bypass | Cardiovascular | 870.4210 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66338 | Mitral/tricuspid annuloplasty ring, open-surgery | A circular band intended to be implanted in the heart during open heart surgery to support a mitral or tricuspid valve annulus for the reconstruction and/or remodelling of insufficient and/or stenotic mitral or tricuspid valves. It is typically mounted on a disposable holder assembly or preloaded in a disposable delivery system to enable it to maintain its shape and aid in its implantation with sutures or anchors. The device may be semi-rigid or flexible and may include metallic, polymeric, and/or textile materials; it is available in various sizes. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00763000193232 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K924642 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 50.0 | Centimeter | |
| Catheter Gauge | 27.0 | French |
Storage Conditions
- Type
- Handling Environment Temperature
- Temperature Range
- – 40 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Store the product at room temperature.