FDA UDI
In Commercial Distribution
🇺🇸 United States
GORE VIABAHN VBX Balloon Expandable Endo
DI: 00733132637232
·
Model: BXA071502A
·
W. L. Gore & Associates, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- GORE VIABAHN VBX Balloon Expandable Endo
- Primary DI
- 00733132637232
- Version / Model
- BXA071502A
- Catalog Number
- BXA071502A
- Company Name
- W. L. Gore & Associates, Inc.
- Labeler DUNS
- 967358115
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-01-31
- Public Version
- 11
- Public Version Date
- 2024-12-11
- Public Version Status
- Update
- Public Device Record Key
- d006446e-64a6-4774-aa67-32491dd14168
Device Description
VIABAHN BX BALLOON EXP ENDO 7mmX15mm 7Fr 135cmCath Heparin
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| PRL | Iliac Covered Stent, Arterial | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66619 | Peripheral artery endovascular stent-graft, drug-coated | A non-bioabsorbable tubular implantable device intended to maintain patency and improve luminal diameter of a peripheral artery (excludes aorta, coronary, pulmonary, and intracranial arteries), and that includes a heparin coating intended to prevent thrombotic vessel re-narrowing. It may be intended for implantation in an artery adjacent to the aorta (e.g., iliac, renal arteries), however it is not a dedicated component of an aortoiliac stent-graft assembly; it may additionally be intended for venous implantation. It is comprised of a metallic outer mesh-like structure with an inner synthetic polymer tube (endovascular graft). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00733132637232 | GS1 |
Customer Contacts
- Phone
- 800-528-8763
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P160021 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Catheter Working Length: 135 CM | ||
| Catheter Gauge | 7 | French | |
| Outer Diameter | 7 | Millimeter | |
| Length | 15 | Millimeter |