FDA UDI
In Commercial Distribution
🇺🇸 United States
GORE PROPATEN Vascular Graft
DI: 00733132607341
·
Model: IRTH066060A
·
W. L. Gore & Associates, Inc.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- GORE PROPATEN Vascular Graft
- Primary DI
- 00733132607341
- Version / Model
- IRTH066060A
- Catalog Number
- IRTH066060A
- Company Name
- W. L. Gore & Associates, Inc.
- Labeler DUNS
- 967358115
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-13
- Public Version
- 9
- Public Version Date
- 2025-12-25
- Public Version Status
- Update
- Public Device Record Key
- 789d88d0-4f68-4d17-a13b-d6e8e62735ac
Device Description
PROPATEN VASCULAR GRAFT TW IR 6mmX60cm 60cm Rings Heparin
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- Yes
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DSY | PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER | Cardiovascular | 870.3450 | 2 |
| DYF | Prosthesis, Vascular Graft, Of Less Then 6mm Diameter | Cardiovascular | 870.3450 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35281 | Synthetic vascular graft, non-medicated | An implantable artificial substitute for a blood vessel intended to replace, bypass or shunt a portion of peripheral vasculature (excludes coronary and cerebral arteries) due to a disease, injury, or for haemodialysis access. It is made of synthetic polymer materials [e.g., woven or knitted polyethylene terephthalate (Dacron) or polytetrafluoroethylene (PTFE) fabrics]; it does not contain any pharmaceuticals and does not incorporate a metallic mesh (i.e., it is not a stent-graft). | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00733132607341 | GS1 |
Customer Contacts
- Phone
- +1(800)528-8763
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 60 | Centimeter | |
| Lumen/Inner Diameter | 6 | Millimeter |