FDA UDI
In Commercial Distribution
🇺🇸 United States
enspire
DI: 00724995217440
·
Model: enspire 300 Series
·
Corporation Steris Canada
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- enspire
- Primary DI
- 00724995217440
- Version / Model
- enspire 300 Series
- Catalog Number
- ENHLD300208VWD
- Company Name
- Corporation Steris Canada
- Labeler DUNS
- 202659140
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-04-17
- Public Version
- 3
- Public Version Date
- 2024-08-26
- Public Version Status
- Update
- Public Device Record Key
- 8ad43e66-3c15-458e-a158-5ec86c6ee2d0
Device Description
The enspire 300 Series Automated Endoscope Reprocessor 208V, Vented, Wall Drain is designed to effectively test, clean, high level disinfect, rinse and air purge up to two heat-sensitive, immersible, reusable, semi-critical devices including, but not limited to, GI flexible endoscopes such as bronchoscopes, gastroscopes, and duodenoscopes; or up to six non-channeled naso-endoscopes.
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MED | Sterilant, medical devices | General Hospital | 880.6885 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66649 | Endoscope washer-disinfector (chemical) | An electrically-powered unit intended to be used for both washing and chemical disinfection of endoscopes, and their accessories. It has built-in features to circulate cleaning and disinfectant solutions through the lumen (flushing) of the endoscope; some types may also have built-in drying features. It is not intended for device sterilization. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00724995217440 | GS1 |
Customer Contacts
- Phone
- +1(800)548-4873
- [email protected]