FDA UDI
In Commercial Distribution
🇺🇸 United States
Heated Circuit
DI: 00709078001086
·
Model: 9313
·
WESTMED, INC.
Product Codes
3
GMDN Terms
3
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- Heated Circuit
- Primary DI
- 00709078001086
- Version / Model
- 9313
- Company Name
- WESTMED, INC.
- Labeler DUNS
- 092673953
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-11-24
- Public Version
- 5
- Public Version Date
- 2022-10-24
- Public Version Status
- Update
- Public Device Record Key
- 3bba506c-dbb6-42f6-aaa6-c74a063f9d0e
Device Description
72` Ped.Htd Wick,BV,1LF,3pk ECG,GSL,14FR.O2 cath.,24` tube
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| CAH | Filter, Bacterial, Breathing-Circuit | Anesthesiology | 868.5260 | 2 |
| BZE | Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer | Anesthesiology | 868.5270 | 2 |
| OFP | Anesthesia Breathing Circuit Kit (Adult & Pediatric) | Anesthesiology | 868.5240 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 37704 | Anaesthesia breathing circuit, single-use | An assembly of devices designed to conduct medical gases from an anaesthesia unit/workstation to a patient artificial airway/anaesthesia mask (not included) during general anaesthesia. It includes breathing tubes and a Y-piece connector, typically with a ventilator/ventilation bag and appropriate connectors, and may include a carbon dioxide (CO2) absorber, a one-way directional valve, or adjustable pressure limiting (APL) valve. This is a single-use device. | No | Active |
| 60965 | Respiratory gas heating wire, infant | A non-sterile device intended to be integrated within a ventilator breathing circuit and used in conjunction with a heated respiratory humidifier (from which it draws its power) to maintain the temperature of inspiratory gasses during ventilation of an infant/neonate. It typically consists of a compact heating unit which and a length of heated wire which is integrated within the lumen of a neonatal/paediatric breathing circuit tube. This is a reusable device. | No | Active |
| 46816 | Heat/moisture exchanger/microbial medical gas filter | A device intended to be placed within a breathing circuit proximal to the patient, to remove and retain microbes whilst capturing the patient's exhaled heat and moisture so that they can be used to heat and humidify the therapeutic gases inspired by the patient. It is typically a plastic housing which contains both a bidirectional microbial filter, intended to reduce the risk of cross-contamination between patients, and a heat/moisture exchanger (HME), intended to maintain the mucous membranes of the respiratory tract. It is typically used during anaesthesia or periods of prolonged respiratory support/therapy. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 10709078001083 | GS1 | 18 | In Commercial Distribution | ||
| Primary | 00709078001086 | GS1 |