FDA UDI
In Commercial Distribution
🇺🇸 United States
AIMSCREEN MULTIDRUG 10
DI: 00695684401252
·
Model: 40125
·
GERMAINE LABORATORIES, INC
Product Codes
9
GMDN Terms
10
Identifiers
2
Pkg Device Count
25
Basic Information
- Brand Name
- AIMSCREEN MULTIDRUG 10
- Primary DI
- 00695684401252
- Version / Model
- 40125
- Company Name
- GERMAINE LABORATORIES, INC
- Labeler DUNS
- 176458115
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 25
- Record Status
- Published
- Publish Date
- 2016-05-12
- Public Version
- 5
- Public Version Date
- 2022-11-28
- Public Version Status
- Update
- Public Device Record Key
- 2f289311-6eb8-4cff-b24b-404369fe37a2
Device Description
Lateral flow immunoassay for the detection of drugs of abuse in urine: Cocaine (COC), Amphetamine (AMP), Methamphetamine (mAMP), Marijuana (THC), Methadone (MTD), Opiates (OPI), Phencyclidine (PCP), Barbiturates (BAR), Benzodiazpines (BZO), Ecstasy (MDMA).
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXM | Enzyme Immunoassay, Benzodiazipine | Clinical Toxicology | 862.3170 | 2 |
| DIS | Enzyme Immunoassay, Barbiturate | Clinical Toxicology | 862.3150 | 2 |
| LCM | Enzyme Immunoassay, Phencyclidine | Unknown | U | |
| DKZ | Enzyme Immunoassay, Amphetamine | Clinical Toxicology | 862.3100 | 2 |
| DJG | Enzyme Immunoassay, Opiates | Clinical Toxicology | 862.3650 | 2 |
| DIO | Enzyme Immunoassay, Cocaine And Cocaine Metabolites | Clinical Toxicology | 862.3250 | 2 |
| LAF | Gas Chromatography, Methamphetamine | Clinical Toxicology | 862.3610 | 2 |
| LDJ | Enzyme Immunoassay, Cannabinoids | Clinical Toxicology | 862.3870 | 2 |
| LFG | Radioimmunoassay, Tricyclic Antidepressant Drugs | Clinical Toxicology | 862.3910 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 30519 | Cannabinoid/cannabinoid metabolite IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of cannabinoids and/or cannabinoid metabolites (i.e., natural, synthetic) in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30524 | Tricyclic antidepressant IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of tricyclic antidepressant drugs in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30517 | Barbiturate IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of barbiturates in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30523 | Phencyclidine (PCP) IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of phencyclidine (PCP) in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30521 | Methadone IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of methadone in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30518 | Benzodiazepine group IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of benzodiazepine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30516 | Amphetamine-specific IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of a specific amphetamine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30522 | Opiate/opiate metabolite IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of opiate and/or opiate metabolites in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 55498 | Methamphetamine-specific IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of a specific methamphetamine in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
| 30520 | Cocaine/cocaine metabolite IVD, kit, rapid ICT, clinical | A collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of cocaine and/or cocaine metabolites in a clinical specimen within a short period, relative to standard laboratory testing procedures, using an immunochromatographic test (ICT) method [lateral flow test]. This is a rapid test used in the laboratory or in point-of-care analyses. It is not intended to be used for self-testing. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00695684401252 | GS1 | ||||
| Unit of Use | 00695684401251 | GS1 |