FDA UDI
In Commercial Distribution
🇺🇸 United States
EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (THV)
DI: 00690103194364
·
Model: 9600TFX
·
Edwards Lifesciences LLC
Product Codes
3
GMDN Terms
5
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (THV)
- Primary DI
- 00690103194364
- Version / Model
- 9600TFX
- Catalog Number
- 9600TFX29A
- Company Name
- Edwards Lifesciences LLC
- Labeler DUNS
- 134139174
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-07-05
- Public Version
- 11
- Public Version Date
- 2022-07-04
- Public Version Status
- Update
- Public Device Record Key
- a8a9aa1f-f3a0-4ce2-84d3-79a94e5eedda
Device Description
EDWARDS SAPIEN 3 TRANSCATHETER HEART VALVE (29MM)
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| NPU | Prosthesis, Mitral Valve, Percutaneously Delivered | Unknown | 3 | |
| NPT | Aortic valve, prosthesis, percutaneously delivered | Unknown | 3 | |
| NPV | Pulmonary Valve Prosthesis Percutaneously Delivered | Unknown | f |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60247 | Pulmonary transcatheter heart valve bioprosthesis | An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed or regurgitant pulmonary heart valve prosthesis (previously implanted), or native pulmonary valve anatomy that may have been surgically repaired, and which is designed to be implanted with a catheter via vascular access. It may be attached to an expandable metal framework which may be expanded with a balloon or self-expand, and may include other material types (e.g., synthetic polymer). Devices associated with implantation (e.g., catheter, introducer) may be included. | Yes | Active |
| 60245 | Aortic transcatheter heart valve bioprosthesis, stent-like framework | An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed and/or regurgitant aortic heart valve, or previously-implanted aortic heart valve prosthesis, and which is designed to be implanted with a catheter via transarterial access (e.g., femoral, subclavian, aortic) or transapical access while the heart is beating. It is comprised of the xenograft, processed to render the tissue non-viable, attached to an expandable metal framework, which is implanted with an included catheter, and when in situ, may be expanded with a balloon or self-expand. Typically devices associated with implantation (e.g., catheter, introducer) are included. | Yes | Active |
| 58865 | Vascular catheter introduction set, nonimplantable | A collection of sterile, nonimplantable, invasive devices intended to provide percutaneous vascular access to enable introduction of a catheter (not included) into the vascular system. It includes a non-steerable introducer sheath with an inner obturator/dilator, and typically an additional access device(s) [e.g., guidewire, introducer needle, syringe, additional dilators] which may include a haemostatic valve to control blood loss, usually to enable arterial access. This is a single-use device. | No | Active |
| 60246 | Mitral transcatheter heart valve bioprosthesis | An implantable xenograft (e.g., bovine) intended to be used to repair/replace a stenosed or regurgitant mitral heart valve, or previously-implanted mitral heart valve prosthesis, and which is implanted with a catheter via percutaneous access (e.g., transfemoral, transapical) while the heart is beating. It is comprised of the xenograft, processed to render the tissue non-viable, attached to a metal framework (which may be covered with a synthetic polymer material) that is expandable in situ; it may also include a synthetic polymer subannular valve anchoring component. Devices to assist implantation (e.g., catheter, introducer) are typically included. | Yes | Active |
| 16463 | Basic crimper | A hand-held manual device designed to compress (pinch) a non-patient-contact sealing device (e.g., a clip or crimping ring of metal applied apart from the body) to reduce its size (diameter) and create a tight seal on objects being clamped or held together. This is performed by the application of force on the grip of the crimper's handles by the operator. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00690103194364 | GS1 |
Customer Contacts
- Phone
- +1(800)822-9637
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 29 MM |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 25 Degrees Celsius