FDA UDI
In Commercial Distribution
🇺🇸 United States
n/a
DI: 00681490520089
·
Model: 8756412
·
MEDTRONIC SOFAMOR DANEK, INC.
Product Codes
1
GMDN Terms
2
Identifiers
1
Pkg Device Count
1
Let the assistant research this device
The Research Assistant compiles product codes, classification, clearances and adverse events for this device — and cites every record.
Free to try · every answer cites its records
Basic Information
- Brand Name
- n/a
- Primary DI
- 00681490520089
- Version / Model
- 8756412
- Company Name
- MEDTRONIC SOFAMOR DANEK, INC.
- Labeler DUNS
- 830350380
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-12-20
- Public Version
- 1
- Public Version Date
- 2024-12-30
- Public Version Status
- New
- Public Device Record Key
- 05416ace-6422-461e-afac-9c9c49872307
Device Description
INSTRUMENT 8756412 DISTRACTOR PIN 12MM
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LXH | Orthopedic manual surgical instrument | Orthopedic | 888.4540 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 33968 | Surgical screwdriver, reusable | A non-powered tool intended to fit into a screw head (e.g., slotted, cross/hex head) for the application of rotation to introduce/remove a screw (e.g., craniofacial bone screw, dental screw) into/from a patient in association with a surgical procedure [e.g., orthopaedic, dental, computer assisted surgery (CAS), image registration]. It may also be used to connect/disconnect a device to/from another device attached to a patient (e.g., implant component, fiducial marker). The proximal end of the device may have a handle for manual use or a profiled tang that fits into an independent chuck or power driver; it is typically made of metallic and/or polymer materials. This is a reusable device. | No | Active |
| 56637 | Orthopaedic surgical distractor, internal | A hand-held manual surgical instrument designed to invasively distract (force apart) two bone surfaces to enable a surgical procedure. It typically aids in fracture reduction by helping to temporarily stabilize bones prior to definitive surgical fixation. It typically consists of a central threaded spindle, a static endpiece and a sliding carriage that can be adjusted using spindle nuts to/from the endpiece to widen or shorten the gap; it facilitates the attachment of orthopaedic bone pins (Schanz screws) screwed into the bones to be distracted. It is typically used for multiple injuries when it is advantageous to perform procedures on a standard operating table. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00681490520089 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]