FDA UDI
In Commercial Distribution
🇺🇸 United States
Radians
DI: 00674326398686
·
Model: RWG9114
·
Radians, Inc.
Product Codes
2
GMDN Terms
1
Identifiers
3
Pkg Device Count
50
Basic Information
- Brand Name
- Radians
- Primary DI
- 00674326398686
- Version / Model
- RWG9114
- Catalog Number
- RWG9114XL
- Company Name
- Radians, Inc.
- Labeler DUNS
- 044600976
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 50
- Record Status
- Published
- Publish Date
- 2025-01-22
- Public Version
- 1
- Public Version Date
- 2025-01-30
- Public Version Status
- New
- Public Device Record Key
- 88dfa7e0-9716-41ba-8ed7-59f5c42a37d0
Device Description
Powder Free Latex Examination Gloves, Blue, Non Sterile. 14 Mil. Extended Cuff. Finger Textured Grip. Single Use. Size X-Large. Tested for Use with Chemotherapy Drugs per ASTM D6978
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- No
- Over the Counter (OTC)
- Yes
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- Yes
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LYY | Latex Patient Examination Glove | General Hospital | 880.6250 | 1 |
| LZC | Medical Glove, Specialty | General Hospital | 880.6250 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 47172 | Hevea-latex examination/treatment glove, non-powdered, non-antimicrobial | A device made of Hevea natural rubber latex (NRL) intended as a protective barrier when worn on the hands of healthcare providers during patient examination/treatment or for other sanitary purposes; its inner surface is not covered with powder and it does not include antimicrobial agents/materials. The device is used mainly as a two-way barrier to protect both the patient and the staff against various contamination. It will have appropriate characteristics regarding tactility/comfort of use, and should provide appropriate physical properties (e.g., strength, elasticity), and uniformity of dimensions. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 10674326398683 | GS1 | Case | 10 | In Commercial Distribution | |
| Primary | 00674326398686 | GS1 | ||||
| Unit of Use | 90674326398689 | GS1 |
Customer Contacts
- Phone
- 901-388-7776
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | X-Large | ||
| Width | 116 | Millimeter |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- 10 – 30 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Shield gloves from direct sunlight, fluorescent light, x-rays, moisture, and ozone.