FDA UDI
In Commercial Distribution
🇺🇸 United States
Capstone Control PTC Spinal System
DI: 00643169679887
·
Model: 5001527
·
MEDTRONIC SOFAMOR DANEK, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Capstone Control PTC Spinal System
- Primary DI
- 00643169679887
- Version / Model
- 5001527
- Company Name
- MEDTRONIC SOFAMOR DANEK, INC.
- Labeler DUNS
- 830350380
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-09-01
- Public Version
- 2
- Public Version Date
- 2023-11-02
- Public Version Status
- Update
- Public Device Record Key
- 7f7aa6fa-a8ca-4221-973d-b5abc0b0cfe1
Device Description
SPACER 5001527 CONTROL PTC 6 DEG 15X27
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- Yes
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| MAX | Intervertebral fusion device with bone graft, lumbar | Orthopedic | 888.3080 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60762 | Polymeric spinal interbody fusion cage | A device intended to be implanted into the space of an intervertebral disc that has been partially or totally removed during surgery in order to allow bone fusion between two contiguous vertebral bodies, typically in the treatment of degenerative disc disease (DDD). It is in the form of a hollow, porous, threaded and/or fenestrated cylindrical or geometrical device made of non-bioabsorbable synthetic polymer [e.g., polyetheretherketone (PEEK)] that provides mechanical stability and sufficient space for therapeutic spinal bone fusion to occur; bone graft is typically used to help with osseointegration. Fixation screws and devices associated with implantation may be included with the device. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00643169679887 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K171107 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 27.0 | Millimeter | |
| Height | 15.0 | Millimeter | |
| Angle | 6.0 | degree |