FDA UDI
In Commercial Distribution
🇺🇸 United States
Freezor® Xtra
DI: 00643169672468
·
Model: 227F1
·
MEDTRONIC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Freezor® Xtra
- Primary DI
- 00643169672468
- Version / Model
- 227F1
- Company Name
- MEDTRONIC, INC.
- Labeler DUNS
- 006261481
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2017-02-16
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- dd1f7846-1eb7-4197-b624-5000c965f0d4
Device Description
CATHETER 227F1 FREEZOR XTRA1 SH 7F
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| LPB | Cardiac ablation percutaneous catheter | Unknown | 3 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 60720 | Cardiac cryosurgical system catheter | A sterile, flexible device intended to be used as part of a cardiac tissue cryosurgical system to cryogenically ablate areas of the endocardium of a beating heart in the treatment of cardiac arrhythmias. It is intended to be introduced into the heart via venous access (e.g., femoral vein) and deliver pressurized liquid refrigerant (e.g., nitrous oxide) to its distal cooling segment to achieve extremely low temperatures through gas expansion; it typically includes sensors (e.g., temperature monitoring). This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00643169672468 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| P020045 | 073 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | catheter curve 49mm | ||
| Device Size Text, specify | catheter tip length 6mm | ||
| Catheter Gauge | 7.0 | French | |
| Length | 108.0 | Centimeter |
Storage Conditions
- Type
- Storage Environment Humidity
- Temperature Range
- – 85 Percent (%) Relative Humidity
- Type
- Handling Environment Humidity
- Temperature Range
- – 85 Percent (%) Relative Humidity
- Type
- Special Storage Condition, Specify
- Special Conditions
- Fragile handle with care
- Type
- Handling Environment Temperature
- Temperature Range
- -35 – 58 Degrees Celsius
- Type
- Storage Environment Temperature
- Temperature Range
- 15 – 30 Degrees Celsius
- Type
- Special Storage Condition, Specify
- Special Conditions
- Keep dry