FDA UDI
In Commercial Distribution
🇺🇸 United States
NA
DI: 00643169646322
·
Model: 6212-S5
·
MEDTRONIC, INC.
Product Codes
1
GMDN Terms
1
Identifiers
2
Pkg Device Count
1
Basic Information
- Brand Name
- NA
- Primary DI
- 00643169646322
- Version / Model
- 6212-S5
- Company Name
- MEDTRONIC, INC.
- Labeler DUNS
- 006261481
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-02-06
- Public Version
- 2
- Public Version Date
- 2024-02-05
- Public Version Status
- Update
- Public Device Record Key
- bf16bf63-af00-4a3b-85bf-2c63ebffec4e
Device Description
LEAD INTRODUCER KIT SPLIT 6212-S5 GLBL
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- Yes
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DYB | INTRODUCER, CATHETER | Cardiovascular | 870.1340 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 46801 | Subcutaneous tunneller, single-use | A hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt). It is available in a variety of forms and may be: 1) a luminal sheath with a removable inner obturator, intended for co-axial device introduction, followed by sheath removal; or 2) a non-luminal device intended to either lead or pull the device through subcutaneous tissue. It is not intended for tunnelling through deep tissues and is not a dedicated pacing or defibrillation lead tunneller. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 20643169646326 | GS1 | PK | 5 | In Commercial Distribution | |
| Primary | 00643169646322 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K965167 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | Introducer inner diameter 12 French |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- – 40 Degrees Celsius