FDA UDI
Not in Commercial Distribution
🇺🇸 United States
DIVERGENCE™ ANTERIOR CERVICAL FUSION SYSTEM
DI: 00643169516366
·
Model: 77367412
·
MEDTRONIC SOFAMOR DANEK, INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- DIVERGENCE™ ANTERIOR CERVICAL FUSION SYSTEM
- Primary DI
- 00643169516366
- Version / Model
- 77367412
- Company Name
- MEDTRONIC SOFAMOR DANEK, INC.
- Labeler DUNS
- 830350380
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-08-18
- Public Version
- 7
- Public Version Date
- 2022-10-13
- Public Version Status
- Update
- Public Device Record Key
- e45d8450-98f3-4091-ae1f-56b5f8422a7e
- Distribution End Date
- 2022-09-26
Device Description
TRIAL 77367412 DIVERGE 6 DEG 11-12X17X14
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| ODP | Intervertebral fusion device with bone graft, cervical | Orthopedic | 888.3080 | 2 |
| KWQ | APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY | Orthopedic | 888.3060 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 12696 | Orthopaedic implant inserter/extractor, reusable | A hand-held manual surgical instrument designed to insert or extract an implantable orthopaedic device (e.g., a bone nail, spiral blade, or bone fixation plate) through application of a striking or screwing force. It is an instrument in a one-piece or modular configuration with a mechanism that will attach and/or lock to part of the implant, and a mechanism to apply the striking force (e.g., on a pad/flange) using a surgical hammer or a weight that can slide along a shaft, or a mechanism for twisting (screwing) (e.g., T-handle). This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00643169516366 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K142450 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Device Size Text, specify | 6DEG 11-12mm x 17mm x14mm |