FDA UDI
In Commercial Distribution
🇺🇸 United States
Indigo™
DI: 00613994933706
·
Model: 1845010
·
MEDTRONIC XOMED, INC.
Product Codes
5
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Indigo™
- Primary DI
- 00613994933706
- Version / Model
- 1845010
- Company Name
- MEDTRONIC XOMED, INC.
- Labeler DUNS
- 835465063
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-05-13
- Public Version
- 5
- Public Version Date
- 2023-11-20
- Public Version Status
- Update
- Public Device Record Key
- 80c62164-3264-429c-9cc3-844990064b2d
Device Description
ATTACHMENT 1845010 INDIGO OTOL STRAIGHT
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- Yes
- Has Lot/Batch Number
- No
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Moist Heat or Steam Sterilization", "Ethylene Oxide"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HBE | DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) | Neurology | 882.4310 | 2 |
| HBC | MOTOR, DRILL, ELECTRIC | Neurology | 882.4360 | 2 |
| ERL | DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE | Ear, Nose, Throat | 874.4250 | 2 |
| HRX | ARTHROSCOPE | Orthopedic | 888.1100 | 2 |
| HWE | INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT | General, Plastic Surgery | 878.4820 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 41267 | Surgical power tool system control unit, pneumatic | A pneumatically-powered (gas-powered) component of a surgical power tool system intended to regulate the gas pressure supplied to the pneumatic handpiece/motor (not included) and may also be intended to regulate some of the functions of the connected power tools (e.g., speed and torque); it may be intended for single or multiple clinical applications (i.e., dedicated or non-dedicated). This device may have integrated irrigation functionality and may be operated through hand and/or foot controls. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00613994933706 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K081277 | 000 |