FDA UDI
In Commercial Distribution
🇺🇸 United States
Becker®
DI: 00613994806642
·
Model: 46115
·
MEDTRONIC PS MEDICAL, INC.
Product Codes
2
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Becker®
- Primary DI
- 00613994806642
- Version / Model
- 46115
- Company Name
- MEDTRONIC PS MEDICAL, INC.
- Labeler DUNS
- 089055867
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2015-07-02
- Public Version
- 4
- Public Version Date
- 2021-07-22
- Public Version Status
- Update
- Public Device Record Key
- 57a3f076-ca0a-4e16-a178-3a0a2db7d3e4
Device Description
EDMS 46115 BECKER VENT CATH 20CM
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| JXG | Shunt, central nervous system and components | Neurology | 882.5550 | 2 |
| GWM | DEVICE, MONITORING, INTRACRANIAL PRESSURE | Neurology | 882.1620 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61399 | Intracerebral infusion/drainage catheter, short-term | A flexible tube intended to be surgically inserted through the skull for short-term (= 30 days) subdural access to the brain (e.g., cerebral ventricles, cystic tumours) for cerebrospinal fluid (CSF) drainage and/or infusion of materials (e.g., chemotherapeutic agents); it may also be intended for measurement of intracranial pressure (ICP). It may include an attached port/reservoir at its proximal end that is placed subcutaneously to facilitate material infusion/collection, and/or accessory devices intended to facilitate catheter introduction and/or stabilization (e.g., stylet, bolts, drills, catheter holder); it does not include a sensor. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00613994806642 | GS1 |
Customer Contacts
- Phone
- +1(800)633-8766
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K984053 | 000 |