FDA UDI
In Commercial Distribution
🇺🇸 United States
Sensor
DI: 00606959010079
·
Model: AIR FLOW SENSOR 1 CHANNEL NEONATE
·
Respironics, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Sensor
- Primary DI
- 00606959010079
- Version / Model
- AIR FLOW SENSOR 1 CHANNEL NEONATE
- Catalog Number
- P1214
- Company Name
- Respironics, Inc.
- Labeler DUNS
- 080728314
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-06
- Public Version
- 4
- Public Version Date
- 2021-01-28
- Public Version Status
- Update
- Public Device Record Key
- 11d104f6-90d5-401c-86f0-b2185e2b843c
Device Description
Thermocouple Air Flow Sensor 1, Neonate
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- Yes
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| BZG | SPIROMETER, DIAGNOSTIC | Anesthesiology | 868.1840 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 35872 | Airway temperature monitoring system | An assembly of devices typically used bedside to continuously measure the temperature at a specific point along a ventilation airway (e.g., inspiratory limb, Y-piece). It typically includes a temperature sensor, a transducer, a cable, and an electronic unit with a display and alarms (audible and/or visual). The system provides real-time information on the temperature of the gases supplied to patients under assisted ventilation, particularly when a heated humidifier is incorporated into the inspiratory line of a patient's breathing circuit. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00606959010079 | GS1 |
Customer Contacts
- Phone
- +1(724)744-2500
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K913396 | 000 |
Storage Conditions
- Type
- Storage Environment Temperature
- Temperature Range
- -4 – 140 Degrees Fahrenheit
- Type
- Storage Environment Humidity
- Temperature Range
- 15 – 95 Percent (%) Relative Humidity
- Type
- Storage Environment Temperature
- Temperature Range
- -20 – 60 Degrees Celsius