FDA UDI
In Commercial Distribution
🇺🇸 United States
BD Safety-Lok™ Infusion Set with Filter
DI: 00382904726003
·
Model: 47260025
·
BECTON, DICKINSON AND COMPANY
Product Codes
1
GMDN Terms
1
Identifiers
3
Pkg Device Count
1
Basic Information
- Brand Name
- BD Safety-Lok™ Infusion Set with Filter
- Primary DI
- 00382904726003
- Version / Model
- 47260025
- Catalog Number
- 47260025
- Company Name
- BECTON, DICKINSON AND COMPANY
- Labeler DUNS
- 001292192
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-16
- Public Version
- 5
- Public Version Date
- 2021-04-07
- Public Version Status
- Update
- Public Device Record Key
- 108bf03d-7bf6-4b13-a478-e9af7d330442
Device Description
SAFETY LOK INFUSION SET WITH FILTER
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- Yes
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- Yes
- Has Donation ID
- No
Sterilization
- Is Sterile
- Yes
- Sterilization Prior Use
- No
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FPA | Set, administration, intravascular | General Hospital | 880.5440 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 58977 | Basic intravenous administration set, noninvasive | A collection of noninvasive devices intended to conduct fluids from an intravenous (IV) administration bag/bottle to a peripheral venous cannula (not included) during gravitational or pump administration to a patient's venous system; some types may in addition be intended for enteral feeding applications. It typically includes tubing, connectors, chambers, and clamps; the bag/bottle may be included. It neither includes devices intended for invasive use nor a heat exchanger. This is a single-use device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Package | 30382904726004 | GS1 | Shelfpack | 50 | In Commercial Distribution | |
| Primary | 00382904726003 | GS1 | ||||
| Package | 50382904726008 | GS1 | Case | 200 | In Commercial Distribution |
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K033350 | 000 |
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Needle Gauge | 25 | Gauge | |
| Length | 12 | Inch | |
| Length | 0.75 | Inch |