FDA UDI
In Commercial Distribution
🇺🇸 United States
Cannulated Headless Screw - Full Thread
DI: 00196449031269
·
Model: 04.345.703
·
Tyber Medical, LLC
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Cannulated Headless Screw - Full Thread
- Primary DI
- 00196449031269
- Version / Model
- 04.345.703
- Company Name
- Tyber Medical, LLC
- Labeler DUNS
- 010968002
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2025-06-06
- Public Version
- 3
- Public Version Date
- 2025-08-15
- Public Version Status
- Update
- Public Device Record Key
- 404d6de3-4b01-411f-b2c8-2d1a4e1a9bc4
Device Description
6.5MM TI CANN HEADLESS SCREW FULL THREAD, 115MM
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- MR Conditional
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HWC | Screw, fixation, bone | Orthopedic | 888.3040 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 66947 | Orthopaedic bone screw (non-sliding) | A small, threaded, non-bioabsorbable, implantable rod intended for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary stabilization of a fractured bone; it is not intended to be introduced through the sleeve of a femoral neck fixation plate/sleeve, not used in dentistry/orthodontics, craniofacial or spinal bones, and not dedicated to intramedullary fixation/arthrodesis. It is typically of cortical or cancellous design and has a drive (e.g., slot, cross, star, polygonal) at its proximal end for introduction with a screwdriver. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00196449031269 | GS1 |
Customer Contacts
- Phone
- +1(866)761-0933
- [email protected]