FDA UDI
In Commercial Distribution
🇺🇸 United States
E3D-A Interbody System
DI: 00195860018002
·
Model: 110-55VB40
·
Evolution Spine LLC
Product Codes
3
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- E3D-A Interbody System
- Primary DI
- 00195860018002
- Version / Model
- 110-55VB40
- Catalog Number
- 110-55VB40
- Company Name
- Evolution Spine LLC
- Labeler DUNS
- 116940934
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2023-03-15
- Public Version
- 2
- Public Version Date
- 2024-02-14
- Public Version Status
- Update
- Public Device Record Key
- 6a05dd52-8bf1-46a6-a35e-5ccbba622a82
Device Description
BLUNT TIP SCREW 5.5 X 40mm
Device Characteristics
- Single Use
- Yes
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| OVD | Intervertebral fusion device with integrated fixation, lumbar | Orthopedic | 888.3080 | 2 |
| PHM | Intervertebral fusion device with bone graft, thoracic | Orthopedic | 888.3080 | 2 |
| MAX | Intervertebral fusion device with bone graft, lumbar | Orthopedic | 888.3080 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 61325 | Bone-screw internal spinal fixation system, non-sterile | An assembly of non-sterile implantable devices intended to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities, also used as an adjunct to spinal fusion [e.g., for degenerative disc disease (DDD)]. Otherwise known as a pedicle screw instrumentation system, it typically consists of a combination of anchors (e.g., bolts, hooks, pedicle screws or other types), interconnection mechanisms (incorporating nuts, screws, sleeves, or bolts), longitudinal members (e.g., plates, rods, plate/rod combinations), and/or transverse connectors. Non-sterile disposable devices associated with implantation may be included. | Yes | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00195860018002 | GS1 |
Customer Contacts
- Phone
- +1(214)682-8536
- [email protected]
Premarket Submissions
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 40 | Millimeter | |
| Outer Diameter | 5.5 | Millimeter |