FDA UDI
Not in Commercial Distribution
🇺🇸 United States
CSU PEDIATRIC BALFOUR RETRACTOR
DI: 00192896048423
·
Model: 1100-611
·
SONTEC INSTRUMENTS, INC.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- CSU PEDIATRIC BALFOUR RETRACTOR
- Primary DI
- 00192896048423
- Version / Model
- 1100-611
- Catalog Number
- 1100-611
- Company Name
- SONTEC INSTRUMENTS, INC.
- Labeler DUNS
- 040729840
- Distribution Status
- Not in Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2018-09-14
- Public Version
- 2
- Public Version Date
- 2023-08-10
- Public Version Status
- Update
- Public Device Record Key
- 47f5ea95-1853-40f7-8773-e07e7fef1302
- Distribution End Date
- 2023-08-09
Device Description
CSU PEDIATRIC BALFOUR RETRACTOR DOUBLE BAR FENESTRATED SIDE BLADES
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- ["Dry Heat Sterilization", "Moist Heat or Steam Sterilization"]
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| FFO | RETRACTOR, SELF-RETAINING | Gastroenterology, Urology | 876.4730 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 45182 | Self-retaining surgical retractor, reusable | A hand-operated, self-retaining, one-piece surgical instrument intended to be used to separate/draw aside the margins of a wound/incision to allow access to tissues/organs during open surgery; it is not intended to retract the ribs and is not dedicated to ophthalmic surgery, but may otherwise be clinically dedicated. It is designed as a one-piece device (i.e., not a mounting ring, or table-fixed assembly) having two legs with distal hooked blades and a self-retaining mechanism to maintain the legs in an open position for retraction. This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00192896048423 | GS1 |
Customer Contacts
- Phone
- +1(800) 821-7496
- [email protected]
Device Sizes
| Type | Value | Unit | Text |
|---|---|---|---|
| Length | 4 | Inch |