FDA UDI
In Commercial Distribution
🇺🇸 United States
Millennium
DI: 00190776383046
·
Model: 92-F2502S
·
Avalign Technologies, Inc.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Millennium
- Primary DI
- 00190776383046
- Version / Model
- 92-F2502S
- Company Name
- Avalign Technologies, Inc.
- Labeler DUNS
- 792528510
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2024-07-24
- Public Version
- 1
- Public Version Date
- 2024-08-01
- Public Version Status
- New
- Public Device Record Key
- cff54c2c-8d81-41fb-bdbe-dbb2980d0303
Device Description
Utrata Capsulorrhexis Forceps, slim, angled 13mm from bend to tip, with slim shafts and extremely thin triangular grasping tips, serrated flat handle, 80mm OL, stainless steel
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| HNR | Forceps, Ophthalmic | Ophthalmic | 886.4350 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 62674 | Ophthalmic soft-tissue manipulation forceps, tweezers-like, reusable | A hand-held manual surgical instrument designed to facilitate the grasping, manipulation, or clamping of, and/or removal of foreign bodies from, ophthalmic soft-tissues (ocular tissues, eyelids), and may be pointed for capsulorhexis. It has a conventional (self-opening) or reverse-action (self-closing) tweezers-like design with variously designed tips, whereby the blades are designed to be opened/closed by squeezing between the fingers (i.e., without ring handles); it is not probe-like in design (i.e., not cannulated). It is typically made of metal, available in various sizes, and may have carbide inserts at the working end. This is a reusable device intended to be sterilized prior to use. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00190776383046 | GS1 |
Customer Contacts
- Phone
- +1(877)289-1096
- [email protected]