FDA UDI
In Commercial Distribution
🇺🇸 United States
Ambler Surgical
DI: 00190660052935
·
Model: Frontal sinus recess giraffe forceps
·
AMBLER SURGICAL CORP.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Ambler Surgical
- Primary DI
- 00190660052935
- Version / Model
- Frontal sinus recess giraffe forceps
- Catalog Number
- 30-384
- Company Name
- AMBLER SURGICAL CORP.
- Labeler DUNS
- 015272206
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2021-01-07
- Public Version
- 2
- Public Version Date
- 2022-06-10
- Public Version Status
- Update
- Public Device Record Key
- d6a8e9f9-d462-4ceb-889d-1ec65eefb6d7
Device Description
Frontal sinus recess giraffe forceps, working length 170mm, curved up 90 degrees, double-action, 2.0mm vertical cup jaws, ring handle
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- Yes
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| KAE | FORCEPS, ENT | Ear, Nose, Throat | 874.4420 | 1 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 36199 | ENT soft-tissue cutting forceps | A hand-held manual surgical instrument with a biting action intended to be used to punch/cut/excise soft-tissue during an ear/nose/throat (ENT) procedure [e.g., adenoidectomy, tonsillectomy, sinus surgery, septoplasty, and/or biopsy]. It is a metallic instrument with a distal mechanism designed to bite tissue when the handles are squeezed together; some types may be used endoscopically (e.g., through a laryngopharyngoscope), and may include an integrated fluid suction channel for improved surgical field viewing. It is not intended for cutting bone (i.e., not a rongeur). This is a reusable device. | No | Active |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00190660052935 | GS1 |
Customer Contacts
- Phone
- +1(888)407-0006 ext. 0
- [email protected]