FDA UDI
In Commercial Distribution
🇺🇸 United States
Ambler Surgical
DI: 00190660014865
·
Model: 17-532
·
AMBLER SURGICAL CORP.
Product Codes
1
GMDN Terms
1
Identifiers
1
Pkg Device Count
1
Basic Information
- Brand Name
- Ambler Surgical
- Primary DI
- 00190660014865
- Version / Model
- 17-532
- Catalog Number
- 17-532
- Company Name
- AMBLER SURGICAL CORP.
- Labeler DUNS
- 015272206
- Distribution Status
- In Commercial Distribution
- Device Count in Pkg
- 1
- Record Status
- Published
- Publish Date
- 2016-09-29
- Public Version
- 3
- Public Version Date
- 2018-07-06
- Public Version Status
- Update
- Public Device Record Key
- 10b94f03-0325-4ffb-9819-f48d81c1556a
Device Description
DeBakey-Derra anastomosis clamp, 6 1/2", large, angled, 2.5cm long x 15.0mm deep atraumatic jaws, ring handle
Device Characteristics
- Single Use
- No
- Prescription Use (Rx)
- Yes
- Over the Counter (OTC)
- No
- Kit
- No
- Combination Product
- No
- HCT/P
- No
- Contains NRL
- No
- Not Made with NRL
- No
- MRI Safety
- Labeling does not contain MRI Safety Information
- Direct Marking Exempt
- No
- PM Exempt
- No
- Has Serial Number
- No
- Has Lot/Batch Number
- Yes
- Has Manufacturing Date
- No
- Has Expiration Date
- No
- Has Donation ID
- No
Sterilization
- Is Sterile
- No
- Sterilization Prior Use
- Yes
- Sterilization Methods
- Moist Heat or Steam Sterilization
Product Codes
| Code | Name | Medical Specialty | Regulation # | Device Class |
|---|---|---|---|---|
| DXC | CLAMP, VASCULAR | Cardiovascular | 870.4450 | 2 |
GMDN Terms
| Code | Name | Definition | Implantable | Status |
|---|---|---|---|---|
| 43142 | Vascular anastomosis clamp | A surgical instrument used to perform a vascular anastamosis (surgical communication between two or more veins or arteries) by compressing the vessels to ensure haemostasis (arrest or prevention of bleeding) before the procedure. It is typically self-retaining and has a scissors-like design with ring handles and blades of various designs (e.g., curved, angled, or semicircular) at the working end, or it may be designed with levers that are locked into position at the site of intervention. It is typically made of high-grade stainless steel and may utilize carbide inserts; it is available in various sizes for different applications. This is a reusable device. | No | Obsolete |
Identifiers
| Type | ID | Issuing Agency | Package Type | Qty per Pkg | Pkg Status | Pkg Discontinue Date |
|---|---|---|---|---|---|---|
| Primary | 00190660014865 | GS1 |
Customer Contacts
- Phone
- +1(888)407-0006 ext. 0
- [email protected]
Premarket Submissions
| Submission Number | Supplement Number |
|---|---|
| K092544 | 000 |