FDA Recall Terminated

SUN DASH RADIUS 252 PN 8000809705. The device is intended to be used for the tanning of human skin.

Recall: Z-2635-2014 · Initiated July 25, 2014

Recall

Recall Number
Z-2635-2014
Event Number
69038
Firm
JK Products & Services, Inc
FEI Number
2311923
Product Code
LEJ
Status
Terminated
Root Cause
Device Design
Initiated
July 25, 2014
Posted
September 12, 2014
Terminated
January 13, 2017
Address
1 Walter Kratz Dr, Jonesboro, AR, 72401-0609

Description

SUN DASH RADIUS 252 PN 8000809705. The device is intended to be used for the tanning of human skin.

Reason

The integrity of the wires inside main electrical chord become compromised from excessive flexing (during the door open/close process).

Action

The owners of the affected device will be notified via certified letter. After the recalling firm confirms ownership, a technician will be dispatched to install a door clamp and door stop, and inspect the condition of the main electrical chord.

Distribution

Nationwide Distribution.

Quantity

1948 units