FDA Recall Open, Classified

GE Healthcare Centricity Radiology RA600 (RA600), Model Numbers: 1) 2022296-001; 2) 2033901-001; 3) 2038437-001; 4) 2038437-011; 5) 2038437-012; 6) 2038437-013; 7) 2038437-014; 8) 2038437-0XX; 9) 2098071-004; 10) 2109571-002; 11) 2109571-006; 12) 2109571-010; 13) 2109594-009; 14) 2109594-011; 15) K2090PS; 16) K2090PTED; 17) MANLEGACY114; 18) MANLEGACY64.

Recall: Z-1485-2025 · Initiated February 19, 2025

Recall

Recall Number
Z-1485-2025
Event Number
96375
Firm
GE Healthcare
FEI Number
3004526608
Product Code
LLZ
Status
Open, Classified
Root Cause
Software design
Initiated
February 19, 2025
Posted
March 28, 2025
Address
500 W Monroe St, Chicago, IL, 60661-3671

Description

GE Healthcare Centricity Radiology RA600 (RA600), Model Numbers: 1) 2022296-001; 2) 2033901-001; 3) 2038437-001; 4) 2038437-011; 5) 2038437-012; 6) 2038437-013; 7) 2038437-014; 8) 2038437-0XX; 9) 2098071-004; 10) 2109571-002; 11) 2109571-006; 12) 2109571-010; 13) 2109594-009; 14) 2109594-011; 15) K2090PS; 16) K2090PTED; 17) MANLEGACY114; 18) MANLEGACY64.

Reason

There is a potential security vulnerability in Centricity Universal Viewer (UV), Centricity PACS-IW (PACS-IW), Centricity Radiology RA600 (RA600), & Centricity Cardiology CA1000 (CA1000) where the service login credentials are able to be identified which could allow a malicious actor with these credentials to access the system and potentially manipulate patient data.

Action

GE Healthcare issued an URGENT MEDICAL DEVICE CORRECTION notice to its consignees on 02/19/2025 by letter delivered using traceable means. The notice explained the issue, safety issue, and requested the following actions be taken: "You can continue to use your device. Please ensure all potential users in your facility are made aware of this safety notification. Please ensure you have implemented the actions below: 1: Ensure your hospital network is secure and 2: Outside of the hospital network implement additional safeguards such as a VPN. Please retain this document for your records. Please complete and return the attached acknowledgement form to [email protected]." "If you have any questions or concerns regarding this notification, please contact GE HealthCare Service at 1-800-437-1171 or your local Service Representative." Per status report 05/23/2025, the firm send a follow-up notice dated 05/13/2025 providing an installation manual addendum that provides instructions for changing passwords.

Distribution

Worldwide distribution.

Quantity

1563 units