FDA Recall Open, Classified

The Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designed for the infusion of the Onyx liquid embolic system (LES). The catheter has a semi-rigid proximal shaft and a highly flexible distal shaft to facilitate the advancement of the catheter in the anatomy. The proximal end of the catheter incorporates a standard Luer adapter to facilitate the attachment of accessories. The outer diameter surface of the catheter is hydrophilically coated to increase lubricity. The AOMC is designed to facilitate catheter retrieval in the event the catheter becomes entrapped within the vasculature. The distal section of the catheter incorporates a detachment zone that allows detachment of the distal tip when the force required to extract the catheter exceeds the force to detach the tip. The catheter has two radiopaque marker bands to visualize the position of the catheter and the detach zone area, one proximal to the detach zone and one at the distal end of the catheter.

Recall: Z-1253-2024 · Initiated January 11, 2024

Recall

Recall Number
Z-1253-2024
Event Number
93922
Firm
Micro Therapeutics, Inc.
FEI Number
1000220862
Product Code
MFE
Status
Open, Classified
Root Cause
Under Investigation by firm
Initiated
January 11, 2024
Posted
March 4, 2024
Address
9775 Toledo Way, Irvine, CA, 92618-1811

Description

The Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designed for the infusion of the Onyx liquid embolic system (LES). The catheter has a semi-rigid proximal shaft and a highly flexible distal shaft to facilitate the advancement of the catheter in the anatomy. The proximal end of the catheter incorporates a standard Luer adapter to facilitate the attachment of accessories. The outer diameter surface of the catheter is hydrophilically coated to increase lubricity. The AOMC is designed to facilitate catheter retrieval in the event the catheter becomes entrapped within the vasculature. The distal section of the catheter incorporates a detachment zone that allows detachment of the distal tip when the force required to extract the catheter exceeds the force to detach the tip. The catheter has two radiopaque marker bands to visualize the position of the catheter and the detach zone area, one proximal to the detach zone and one at the distal end of the catheter.

Reason

European version of microcatheter were distributed within US which contain a different "Indications for Use".

Action

On January 11, 2024, Medtronic Neurovascular issued a "Urgent: Medical Device Recall" Medtronic ask consignees to take the following action: 1. Do not use any impacted product. Remove and quarantine all unused impacted product in your inventory. 2. Return the impacted products to Medtronic. Your Medtronic representative may assist in facilitating the return of product, as necessary. If an alternative product is needed, your Medtronic representative can assist you with identifying a suitable replacement product. 3. Complete and return the Customer Confirmation form enclosed with this letter acknowledging that you have received this information.

Distribution

US Nationwide distribution in the states of AL, AZ, CA, CT, FL, GA, HI, IA, IL, IN, KS, MA, MD, MI, MO, NC, ND, NE, NV, NY, OH, OK, PA, SC, TN, TX, UT, VA, WA, WI.

Quantity

95 units