Ventilator-PLV Continuum (PLVC I), Model Number: P1000. The PLVC I is a microprocessor controlled, compressor-based, mechanical ventilator. It is intended to control or assist breathing by delivering room air to the patient. It utilizes an internal compressor to generate compressed air for delivery to the patient. Breath delivery is controlled by software algorithms. The PL VC I user interface has a membrane keypad with indicator Light Emitting Diodes for the selection and acceptance of patient settings and for the display of alarm conditions. PL VC I provides the following types of ventilatory support: 1) Positive Pressure Ventilation, delivered either invasively (via endotracheal or tracheostomy tube) or non-invasively (via mask or mouthpiece ). 2) Assist/Control, Spontaneous Intermittent Mandatory Ventilation (SIMV)or Continuous Positive Airway Pressure (CPAP) modes of ventilation. 3) Volume-Controlled (VC). Available in AlC and SIMV. 4) Pressure-Controlled (PC). Available in AlC and SIMV. 5) Pressure Support (PS). Available in SIMV and SPONT.

Recall: Z-0808-06 · Initiated March 20, 2006

Recall

Recall Number
Z-0808-06
Event Number
35056
Firm
Respironics California Inc
FEI Number
2518422
Product Code
CBK
Status
Terminated
Root Cause
Other
Initiated
March 20, 2006
Posted
May 2, 2006
Terminated
April 21, 2008
Address
2271 Cosmos Ct, Carlsbad, CA, 92009-1517

Description

Ventilator-PLV Continuum (PLVC I), Model Number: P1000. The PLVC I is a microprocessor controlled, compressor-based, mechanical ventilator. It is intended to control or assist breathing by delivering room air to the patient. It utilizes an internal compressor to generate compressed air for delivery to the patient. Breath delivery is controlled by software algorithms. The PL VC I user interface has a membrane keypad with indicator Light Emitting Diodes for the selection and acceptance of patient settings and for the display of alarm conditions. PL VC I provides the following types of ventilatory support: 1) Positive Pressure Ventilation, delivered either invasively (via endotracheal or tracheostomy tube) or non-invasively (via mask or mouthpiece ). 2) Assist/Control, Spontaneous Intermittent Mandatory Ventilation (SIMV)or Continuous Positive Airway Pressure (CPAP) modes of ventilation. 3) Volume-Controlled (VC). Available in AlC and SIMV. 4) Pressure-Controlled (PC). Available in AlC and SIMV. 5) Pressure Support (PS). Available in SIMV and SPONT.

Reason

Flow valve failures- When failure occurs, air flow from the ventilator ceases resulting in the PLVC I transitioning into a 'Vent Inop' mode whereby the safety valve is activated, opening the circuit to ambient air. Ventilator dependent patients may not receive adequate ventilatory support if this problem occurs.

Action

Notification letters were mailed to customers on March 20, 2006 notifying them of this action. Customers were instructed to quarantine all PLV Continuum Ventilators in their possession and not to place patients on them. Respironics Customers Service will contact customers to arrange for the return of all PLV Continuum Ventilators. Customers were instructed to safely plan and transition patients in their care from the PLV Continum Ventilator onto to other comparable patient support devices. If customers did not have a suitable ventilator to use for their patients, Respironics will loan them a PLV 100, 102 or 102b Ventilator with no charge. If patient support goes beyond the capabilities of the PLV 100, 102, or 102b Ventilator is required, Respironics will make arrangements to loan the customer with a suitable substitute rental ventilator at no charge. The field action will involve the upgrade of all affected devices with a new flow valve assembly. All US and International units are being recalled to the factory in Carlsbad, California. The rework will be conducted on-site.

Distribution

Nationwide, plus Australia, Argentina, Canada, Japan, Hong Kong, Netherlands, Saudi Arabia, & Taiwan

Quantity

Domestic (235) + International Distribution (42)=277 units