FDA Recall Terminated

Sunquest Laboratory versions 5.3, 5.4, 6.1, 6.2 and 6.3. Sunquest Laboratory Information System is comprised of several modules which are involved in aspects such as blood banking, collection management, specimen tracking, and use with microbiology and molecular diagnostics. Key capabilities include: 1) Autoverify results directly from analyzers and reference laboratories 2) Track tubes and containers from order to final disposition 3) Monitor key metrics such as turnaround time and utilization using management reports 4) Produce pathology results with Structured Reports 5) Suggest microbiology workups online according to defined SOPs and rules 6) All data entered into the system is accessible through audit trails and Ad Hoc Report tools 7) Any change to patient results (inquiry, reports) is logged and available for review

Recall: Z-0207-2009 · Initiated April 17, 2008

Recall

Recall Number
Z-0207-2009
Event Number
48174
Firm
Sunquest Information Systems, Inc.
FEI Number
1000306472
Product Code
JQP
Status
Terminated
Root Cause
Component design/selection
Initiated
April 17, 2008
Posted
October 31, 2008
Terminated
December 5, 2011
Address
250 S Williams Blvd, Tucson, AZ, 85711-4472

Description

Sunquest Laboratory versions 5.3, 5.4, 6.1, 6.2 and 6.3. Sunquest Laboratory Information System is comprised of several modules which are involved in aspects such as blood banking, collection management, specimen tracking, and use with microbiology and molecular diagnostics. Key capabilities include: 1) Autoverify results directly from analyzers and reference laboratories 2) Track tubes and containers from order to final disposition 3) Monitor key metrics such as turnaround time and utilization using management reports 4) Produce pathology results with Structured Reports 5) Suggest microbiology workups online according to defined SOPs and rules 6) All data entered into the system is accessible through audit trails and Ad Hoc Report tools 7) Any change to patient results (inquiry, reports) is logged and available for review

Reason

Sunquest has identified a problem with IGO interfaces when performing an Online File Cleanup (OFC) that can lead to the test results of one patient filing to another patient when the order codes are the same. Performing an OFC prior to all results being assigned an accession number may cause the patient results to remain in a temporary file where they can be incorrectly associated to the wrong pat

Action

Customers were sent a preliminary notice on 4/17/2008 followed by customer notice PSN-08-04 on 05/07/2008 via email. The notice advises that this notice is follow-up to the Preliminary notice distributed on 4/17/08 and applies to all clients who have an Instrument Generated Order (IGO) interface. Sunquest has identified a problem with IGO interfaces when performing an Online File Cleanup (OFC) that can lead to the test results of one patient filing to another patient when the order codes are the same. Performing an OFC prior to all results being assigned an accession number may cause the patient results to remain in a temporary file where they can be incorrectly associated to the wrong patient. When this occurs, Sunquest generated reports and inquiry contains the incorrect results. The letter provides the various steps that cause the issue to occur. Sites Potentially Affected by this Problem: Sunquest Laboratory using Instrument Generated Orders (IGO) Interface, Version 5.3 and later Action Sunquest Information Systems is taking to eliminate this Problem: Change Request 1-62VWLJ has been created to address this issue. This will be available as part of Sunquest Laboratory Instrument Build version 1.6.0023 and later. To request the software correction, customers can create a Service request via the Client support Webpage at www.sunquestinfo.com/supportweb. The notice also provides temporary procedural instructions: Effective immediately, do NOT perform Online File Cleanup (OFC) on any IGO instrument interface methods. -Manual OFC should not be performed using functions OFC, or Instrument Maintenance (IX or IXM), option 11 for IGO interfaces only. -If using function Instrument Maintenance (IX or IXM), option 1, 2, 2, Method, 2 (Automatic File Cleanup). This should be set to "N". Then stop and re-start the Instrument Results Processor. Note: Online file cleanup for non-IGO interfaces needs to be performed as usual. -Pending and Overdue Logs need to be monit

Distribution

Worldwide Distribution --- including USA and countries of Canada, Bermuda, Ireland, United Kingdom, United Arab Emirates, and Saudi Arabia.

Quantity

419 clients had the affected code