FDA Recall Terminated

Medtronic Sprint Fidelis 6948 Steroid eluting, quadripolar, ventricular lead with tined tip and right ventricular (RV) / Superior Vena Cava (SVC) defibrillation coil electrodes. Sterile. This lead is designed for pacing, sensing, cardioversion and defibrillation therapies. Medtronic World Headquarters, Medtronic, Inc., 710 Medtronic Parkway, Minneapolis, MN 55432-5604 USA.

Recall: Z-0069-2008 · Initiated October 15, 2007

Recall

Recall Number
Z-0069-2008
Event Number
45403
Firm
Medtronic Inc. Cardiac Rhythm Managment
FEI Number
2182208
Product Code
LWS
Status
Terminated
Root Cause
Device Design
Initiated
October 15, 2007
Posted
October 25, 2007
Terminated
June 21, 2011
Address
7000 Central Ave Ne, Minneapolis, MN, 55432-3568

Description

Medtronic Sprint Fidelis 6948 Steroid eluting, quadripolar, ventricular lead with tined tip and right ventricular (RV) / Superior Vena Cava (SVC) defibrillation coil electrodes. Sterile. This lead is designed for pacing, sensing, cardioversion and defibrillation therapies. Medtronic World Headquarters, Medtronic, Inc., 710 Medtronic Parkway, Minneapolis, MN 55432-5604 USA.

Reason

Medtronic Cardiac Rhythm Disease Management has voluntarily suspended worldwide distribution of the Sprint Fidelis family of defibrillation leads because of the potential for lead fractures. In addition, the company recommends against new implants of the leads (Sprint Fidelis Models: 6930, 6931, 6948, 6949). Medtronic, its Independent Physician Quality Panel, and Bruce Lindsay, M.D., Professor of

Action

A press release was issued by Medtronic on 10/15/2007. An FDA Statement was also issued on 10/15/2007. An Urgent Medical Device Information letter, dated 10/15/2007, was sent to physicians. The letter states that Medtronic has suspended distribution of the leads, the leads should no longer be implanted and unused leads should be returned to Medtronic. This letter describes background information, performance and recommendations. Medtronic believes it is inappropriate to prophylactically remove Sprint Fidelis leads except in unusual individual patient circumstances. An Important Patient Information letter was addressed to Medtronic Heart Device Patients. Both letters can be found on Medtronic's website at www.medtronic.com/fidelis. Return of product will be achieved with the assistance of Medtronic Representatives.

Distribution

Worldwide, including USA, Puerto Rico, Guam, and Northern Mariana Islands.

Quantity

235,000 for all models