FDA Recall Open, Classified

North Star Imaging Inc. (NSI) Model X-7000 industrial cabinet x-ray system. Industrial x-ray imaging of product hardware

Recall: Z-0063-2018 · Initiated August 23, 2017

Recall

Recall Number
Z-0063-2018
Event Number
78254
Firm
North Star Imaging Inc
FEI Number
3009067082
Product Code
RCE
Status
Open, Classified
Root Cause
Radiation Control for Health and Safety Act
Initiated
August 23, 2017
Address
19875 S Diamond Lake Rd, Ste 10, ROGERS, MN, 55374-4651

Description

North Star Imaging Inc. (NSI) Model X-7000 industrial cabinet x-ray system. Industrial x-ray imaging of product hardware

Reason

It was discovered a low-level radiation leak that was found on the NSI X-7000 system.

Action

North Star Imaging will bring defect into compliance by the following : The Center for Devices and Radiological Health (CDRH) understands that the CAP involving 3 units will consist of the following: 1. All three customers have been notified that the affected products will be repaired free of charge. 2 .The area where the emission rate could be exceeded will have shielding added until emissions are adequately attenuated under the conditions described above. 3. The repaired systems will be completely surveyed to verify compliance with the cabinet x- ray system performance standards emission limit. 4.All repairs will be completed before February 1, 2018. For further questions, please call (800) 635-8392.

Distribution

US Distribution to the states of : PA, OH and KS.

Quantity

US - 3 units