FDA Enforcement Class II Terminated

URO-3 Triple Stain (CD44 + p53) with CK20, Catalog #: PM370TSAA, Package Type: Bag, which contains components: a) CD44 + p53, Catalog #: PM373DSAA, Package Type: Bottle, and b) CK20, Catalog #: PM062AA, Package Type: Bottle Product Usage: URO-3 Triple Stain (CD44 + p53) with CK20 is a cocktail of mouse monoclonal and rabbit monoclonal antibodies that is intended for laboratory use in the qualitative identification of CD44, p53 and CK20 proteins by immunohistochemistry (IHC) in formalin-fixed paraffin-embedded (FFPE) human tissues, primarily for bladder cancer characterization. The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient s clinical history and other diagnostic tests by a qualified pathologist. The URO-3 Triple Stain is an adjunct immunohistochemistry test to assist a qualified pathologist in differentiating urothelial reactive atypia from CIS (carcinoma in situ) in suspected bladder lesions. The URO-3 staining pattern will be used as supporting data along with morphological and patient history context for the qualified pathologist to render a diagnosis.

Recall: Z-3198-2018 · Reported September 26, 2018

Enforcement

Recall Number
Z-3198-2018
Event ID
80407
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Biocare Medical, LLC
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
E-Mail
Report Date
September 26, 2018
Initiation Date
March 15, 2018
Classification Date
September 19, 2018
Termination Date
April 22, 2020
Address
60 Berry Dr, N/A, Pacheco, CA, 94553-5601, United States

Description

URO-3 Triple Stain (CD44 + p53) with CK20, Catalog #: PM370TSAA, Package Type: Bag, which contains components: a) CD44 + p53, Catalog #: PM373DSAA, Package Type: Bottle, and b) CK20, Catalog #: PM062AA, Package Type: Bottle Product Usage: URO-3 Triple Stain (CD44 + p53) with CK20 is a cocktail of mouse monoclonal and rabbit monoclonal antibodies that is intended for laboratory use in the qualitative identification of CD44, p53 and CK20 proteins by immunohistochemistry (IHC) in formalin-fixed paraffin-embedded (FFPE) human tissues, primarily for bladder cancer characterization. The clinical interpretation of any staining or its absence should be complemented by morphological studies using proper controls and should be evaluated within the context of the patient s clinical history and other diagnostic tests by a qualified pathologist. The URO-3 Triple Stain is an adjunct immunohistochemistry test to assist a qualified pathologist in differentiating urothelial reactive atypia from CIS (carcinoma in situ) in suspected bladder lesions. The URO-3 staining pattern will be used as supporting data along with morphological and patient history context for the qualified pathologist to render a diagnosis.

Reason

Immunohistochemistry device kits found to display incorrect staining pattern due to mislabeling of two components.

Code Info

Lot: 060617, Expiration: 2019/05 with a) Lot: 060117, and b) 053117

Distribution

Worldwide Distribution - Unites States Nationwide in the states of NY AND FL and the countries of: Morocco and Italy

Quantity

11