FDA Enforcement Class II Terminated

Array LaserLink, Manufactured by Lumenis, The Array" LaserLink" is a laser system accessory intended for use in the treatment of ocular pathology. " For the Posterior Segment, the Array" LaserLink" is indicated for use in Retinal Photocoagulation and Panretinal Photocoagulation of Vascular and Structural Abnormalities of the Retina and Choroid including: " Proliferative and Severe and Very Severe Non-Proliferative Diabetic Retinopathy " Macular Edema associated with Proliferative or Non-Proliferative Diabetic Retinopathy " Choroidal Neovascularization " Retinal Neovascularization associated with Retinal Occlusive Disease (Branch Retinal Vein Occlusion; Central Retinal Vein Occlusion) " Macular Edema associated with Branch Retinal Vein Occlusion " Retinal Tears and Detachments And Anterior Segments as follows: " Iridotomy in Closed Angle Glaucoma " Trabeculoplasty in Open Angle Glaucoma

Recall: Z-2733-2014 · Reported October 8, 2014

Enforcement

Recall Number
Z-2733-2014
Event ID
69139
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Lumenis, Inc.
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
Visit
Report Date
October 8, 2014
Initiation Date
August 15, 2014
Classification Date
September 30, 2014
Termination Date
October 21, 2014
Address
3959 W 1820 S, N/A, Salt Lake City, UT, 84104, United States

Description

Array LaserLink, Manufactured by Lumenis, The Array" LaserLink" is a laser system accessory intended for use in the treatment of ocular pathology. " For the Posterior Segment, the Array" LaserLink" is indicated for use in Retinal Photocoagulation and Panretinal Photocoagulation of Vascular and Structural Abnormalities of the Retina and Choroid including: " Proliferative and Severe and Very Severe Non-Proliferative Diabetic Retinopathy " Macular Edema associated with Proliferative or Non-Proliferative Diabetic Retinopathy " Choroidal Neovascularization " Retinal Neovascularization associated with Retinal Occlusive Disease (Branch Retinal Vein Occlusion; Central Retinal Vein Occlusion) " Macular Edema associated with Branch Retinal Vein Occlusion " Retinal Tears and Detachments And Anterior Segments as follows: " Iridotomy in Closed Angle Glaucoma " Trabeculoplasty in Open Angle Glaucoma

Reason

Lumenis initiated a field-correction for the Array Laser Link", GA-0006700 (SN XXYYZZ) because the system may project an erroneous pattern display on the retina, which is different than the desired pattern.

Code Info

All assembled units since product release, Part Number: GA-0006700.

Distribution

Worldwide Distribution - USA (nationwide) and Internationally to JAPAN, CHINA, and CANADA.

Quantity

16