FDA Enforcement Class II Terminated

Sarns Soft-Flow Extended Aortic Cannulae 7.0mm & 8.0mm with or without luer & Xcoating, Product Usage: The Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.

Recall: Z-2099-2014 · Reported July 30, 2014

Enforcement

Recall Number
Z-2099-2014
Event ID
68404
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Terumo Cardiovascular Systems Corporation
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
Letter
Report Date
July 30, 2014
Initiation Date
May 23, 2014
Classification Date
July 22, 2014
Termination Date
February 24, 2015
Address
6200 Jackson Rd, Ann Arbor, MI, 48103-9586, United States

Description

Sarns Soft-Flow Extended Aortic Cannulae 7.0mm & 8.0mm with or without luer & Xcoating, Product Usage: The Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.

Reason

During an in-process inspection, Terumo Cardiovascular Systems (Terumo CVS) identified the presence of loose fiber particulate that exceeded finished product specifications

Code Info

Part No. 4948, Lot #: 0646471, 0652314, 0652909, 0656645, 0658692, 0662071, 0666665, 0669799, 0672089, 0675750, 0676585, 0678728, 0681792, 0684780, 0685667, 0688001, 0691202, 0693823, 0694711, 0696205, 0698300, 0708186, 0708766, 0710058, 0711914, 0714958, 0716134, 0717932, 0719278, 0721688, 694711R, 696201R; Part No. 4949, Lot #: 0646532, 0650731, 0651656, 0652458, 0655167, 0659823, 0661134, 0666626, 0667247, 0668568, 0669798, 0672411, 0675022, 0677305, 0677868, 0678727, 0681772, 0683304, 0683963, 0685668, 0687773, 0688994, 0694411, 0694706, 0695244, 0698301, 0703802, 0708185, 0708765, 0710054, 0711276, 0715262, 0716637, 0718634, 0720571, 695244R, 696204R; Part No. 4949X, Lot #: 0645381, 0653211, 0661604, 0667107, 0669928, 0684001, 0694715, 0712872, 694715R; Part No. 4950, Lot #: 0648462, 0650495, 0656442, 0657280, 0660743, 0674021, 0678721, 0681807, 0684779, 0687498, 0689723, 0693829, 0698851, 0708778, 0710056, 0711836, 0713283, 0719706, 693829R, 695465R; Part No. 4951, Lot #: 0645876, 0649394, 0653430, 0660668, 0661526, 0667894, 0668979, 0674463, 0675778, 0677306, 0678217, 0681808, 0686128, 0687960, 0694412, 0696144, 0696612, 0698299, 0702118, 0708768, 0710037, 0711275, 0713301, 0722066, 696144R & Part No. 4951X, Lot #: 0668569, 0677303, 0696145, 0712873, 696145R.

Distribution

Worldwide Distribution - US (nationwide) in the states of: AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, PR, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV & WY and the countries of : Australia, Belgium, Canada, Chile, Japan, Malaysia, Mexico, Singapore, Taiwan, Thailand, United Arab Emirates (UAE) & United Kingdom.

Quantity

135,340 units