Bard(R) Adult/Pediatric Feeding Tube, ENFit(TM), REF EN0036420 Product Usage: BARD(R) Nasogastric Sump Tubes with ENFit(TM) connector are intended to be used for: Decompression of stomach by suction or aspiration of gastric contents Short-term administration of term tube feeding, lavage fluid and medications Feeding Tubes with the ENFit(TM) Connector are made of a smooth plastic with a two-eyed tube used for nasogastric feeding of neonates, infants and adults as well as diagnostic and therapeutic aspiration. These products are sold single-use, sterile. The Feeding Tube with the ENFit(TM) connector provides a way to reduce the risk of enteral device misconnections. The ENFit(TM) connector: Addresses patient side connections between feeding tubes, administration sets, medication, flush and bolus feeding syringes, and other enteral devices. Does not allow connectivity with any other connector for any other clinical use.
Enforcement
- Recall Number
- Z-1356-2018
- Event ID
- 79507
- Classification
- Class II
- Status
- Terminated
- Product Type
- Devices
- Firm
- C.R. Bard, Inc.
- Voluntary / Mandated
- Voluntary: Firm initiated
- Initial Notification
- Letter
- Report Date
- April 18, 2018
- Initiation Date
- February 27, 2018
- Classification Date
- April 10, 2018
- Termination Date
- July 11, 2019
- Address
- 8195 Industrial Blvd NE, Covington, GA, 30014-1497, United States
Description
Bard(R) Adult/Pediatric Feeding Tube, ENFit(TM), REF EN0036420 Product Usage: BARD(R) Nasogastric Sump Tubes with ENFit(TM) connector are intended to be used for: Decompression of stomach by suction or aspiration of gastric contents Short-term administration of term tube feeding, lavage fluid and medications Feeding Tubes with the ENFit(TM) Connector are made of a smooth plastic with a two-eyed tube used for nasogastric feeding of neonates, infants and adults as well as diagnostic and therapeutic aspiration. These products are sold single-use, sterile. The Feeding Tube with the ENFit(TM) connector provides a way to reduce the risk of enteral device misconnections. The ENFit(TM) connector: Addresses patient side connections between feeding tubes, administration sets, medication, flush and bolus feeding syringes, and other enteral devices. Does not allow connectivity with any other connector for any other clinical use.
BMD has identified that the product code/lot number combination identified above may have ineffectively fused tubing and ENFit(TM) connector.
Lot Numbers: NGAY4533, NGAX3534, NGARX206
US Nationwide Distribution
3200 units