FDA Enforcement
Class II
Terminated
Columbia Agar with 5% Sheep Blood Columbia Agar with 5% Sheep Blood is a general purpose culture medium used for the growth and recovery of fastidious microbial species.
Recall: Z-0976-2015
·
Reported January 21, 2015
Enforcement
- Recall Number
- Z-0976-2015
- Event ID
- 69091
- Classification
- Class II
- Status
- Terminated
- Product Type
- Devices
- Firm
- Becton Dickinson & Co.
- Voluntary / Mandated
- Voluntary: Firm initiated
- Initial Notification
- Letter
- Report Date
- January 21, 2015
- Initiation Date
- June 6, 2014
- Classification Date
- January 14, 2015
- Termination Date
- August 12, 2016
- Address
- BD Diagnostic Systems, 7 Loveton Circle, Sparks, MD, 21152-0999, United States
Description
Columbia Agar with 5% Sheep Blood Columbia Agar with 5% Sheep Blood is a general purpose culture medium used for the growth and recovery of fastidious microbial species.
Reason
A low level of surface and subsurface contamination of Listeria monocytogenes on 9 lots of non-sterile prepared plated media containing sheep blood, typically visible immediately upon removal from the packaging. The contamination is typically observed as 1-3 CFUs per plate when present.
Code Info
Catalogue # 221263 with Lot #4099228
Distribution
Worldwide Distribution - US nationwide including Puerto Rico, Belgium, Canada, Philippines, Singapore, and Taiwan.
Quantity
775 cases