FDA Enforcement Class II Terminated

Algovita Spinal Cord Stimulation System, Percutaneous Leads, 8-Electrode Percutaneous Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Leads, 12-Electrode Percutaneous Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Trial Leads, 8-electrode Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Trial Leads, 12-electrode Lead Kit. Model Number (s) 112x-xx (CT), 108x-xx(T). These are part of the Algovita Spinal Cord Stimulation System. The Algovita Spinal Cord Stimulation system consists of a stimulator (EPG or IPG) that is physically and electrically connected to one or more leads inserted into the patient s spinal epidural space. The lead delivers electrical stimulation originating at the stimulator with the purpose of blocking pain signals going to the patient s brain. The stimulators are rechargeable, and the frequency of recharging is dependent on individual patient s use of the system.

Recall: Z-0781-2017 · Reported December 28, 2016

Enforcement

Recall Number
Z-0781-2017
Event ID
75459
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Nuvectra
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
Letter
Report Date
December 28, 2016
Initiation Date
October 11, 2016
Classification Date
December 17, 2016
Termination Date
August 8, 2018
Address
10675 Naples St NE, N/A, Blaine, MN, 55449-5802, United States

Description

Algovita Spinal Cord Stimulation System, Percutaneous Leads, 8-Electrode Percutaneous Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Leads, 12-Electrode Percutaneous Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Trial Leads, 8-electrode Lead Kit; Algovita Spinal Cord Stimulation System Percutaneous Trial Leads, 12-electrode Lead Kit. Model Number (s) 112x-xx (CT), 108x-xx(T). These are part of the Algovita Spinal Cord Stimulation System. The Algovita Spinal Cord Stimulation system consists of a stimulator (EPG or IPG) that is physically and electrically connected to one or more leads inserted into the patient s spinal epidural space. The lead delivers electrical stimulation originating at the stimulator with the purpose of blocking pain signals going to the patient s brain. The stimulators are rechargeable, and the frequency of recharging is dependent on individual patient s use of the system.

Reason

Nuvectra is conducting a recall due to two clinical risks that are associated with certain percutaneous leads currently being used in the Algovita Spinal Cord Stimulation System. It has been reported that in some percutaneous leads, the stylet protruded beyond the distal lead tip.

Code Info

Lot Numbers: W2886402 , W2888100 , W2904692, W2909622 , W2909623 , W2912562 , W2918496, W2918506 , W2930816, W2930816 , W2938384 , W2939156 , W2943651 , W2946424 , W2952157 , W2964008 , W2964009, W2964009 , W2964010, W2964010 , W2964011 , W2972187 , W2978500 , W2981155, W2981155 , W2988382, W2988382 , W3040781 , W3041965, W3041965 , W3043467, W3048908, W3052511 , W3052514, W3052515 , W3057023, W3057024, W3057027, W3057033, W3057033 , W3063066, W3063073, W3063073 , W3088964, W3110760 , W3111249, W3114108, W3119243, W3123219 , W3123220, W3123220 , W3124197, W3127472, W3127472 , W3127473, W3133254, W3133264 , W3135521, W3232789, W3232789 , W3232790, W3232791, W3232792, W3232792 , W3236234, W3236235, W3236237, W3236239, W3236239 , W3321458 , W3321459 , W3321460 , W3321461 , W3321463 , W3321464, W3324818 , W3324820, W3324821 , W3324826 , W3324827, W3324829 , W3324830 , W3335022, W3335022 , W3335027, W3335033 , W3335041 , W3335050, W3335050 , W3335055, W3335055 , W3343777, W3343777 , W3348715 , W3356371, W3356371 , W3357155, W3357155 , W3357157 , W3357159, W3357159 , W3357160 , W3357162, W3357164 , W3357167, W3357169 , W3362186 , W3362187, W3362187 , W3362188, W3362188 , W3362209 , W3374818 , W3374820, W3374821 , W3374823 , W3378359, W3378360, W3389104, W3389105 , W3389112, W3389117 , W3393665 , W3393666 , W3393667, W3393668 , W3396586 , W3396603, W3396608, W3396609 , W3399272 , W3424531, W3424531 , W3424542, W3424565 , W3424585, W3424586, W3424586 , W3424589, W3424591 , W3424593, W3424599, W3424602, W3424616 , W3424623 , W3424627 , W3442616 , W3442617, W3442617 , W3442618, W3442618 , W3442619 , W3448170, W3448171, W3448172 , W3448173 , W3448174 , W3454201 , W3454202 , W3462791 , W3462792 , W3462794, W3462795, W3462795 , W3462796, W3462797, W3462798, W3472638, W3472639, W3472639 , W3472640 , W3472641, W3472641 , W3475288, W3475289, W3475289 , W3475290, W3475290 , W3475291, W3475291 , W3493137, W3498560, W3498562, W3498564, W3504760, W3504762, W3504763, W3504766 , W3506847, W3506848, W3506851, W3536038 , W3536039, W3536039 , W3539484, W3540924.

Distribution

US: Nationwide (CA, TX, KY, FL, IL,PA,OH, GA, NJ, NC, KS, AR, CO, NE, NY, VA, AZ, OK). OUS: Germany

Quantity

406 OUS, 985 US