Cardiac Resynchronization Therapy Defibrillators (CRT-Ds), Amplia MRI. Labeled as the following: a. Amplia MRI CRT-D DF4 (Product No. DTMB1D4); b. Amplia MRI Quad CRT-D DF1 (Product No. DTMB1Q1); c. Amplia MRI Quad CRT-D DF4 (Product No. DTMB1QQ); EXPANSION: d. Amplia MRI CRT-D DF1 (Product No. DTMB1D1) Implantable devices that automatically detect and treat episodes of ventricular fibrillation, ventricular tachycardia, fast ventricular tachycardia, and bradyarrhythmia. Some devices can also provide resynchronization therapy, including sequential biventricular pacing (CRT-D devices).
Enforcement
- Recall Number
- Z-0582-2018
- Event ID
- 78888
- Classification
- Class I
- Status
- Terminated
- Product Type
- Devices
- Firm
- Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF)
- Voluntary / Mandated
- Voluntary: Firm initiated
- Initial Notification
- Other
- Report Date
- February 28, 2018
- Initiation Date
- December 19, 2017
- Classification Date
- April 19, 2018
- Termination Date
- August 27, 2021
- Address
- 8200 Coral Sea St Ne, N/A, Mounds View, MN, 55112-4391, United States
Description
Cardiac Resynchronization Therapy Defibrillators (CRT-Ds), Amplia MRI. Labeled as the following: a. Amplia MRI CRT-D DF4 (Product No. DTMB1D4); b. Amplia MRI Quad CRT-D DF1 (Product No. DTMB1Q1); c. Amplia MRI Quad CRT-D DF4 (Product No. DTMB1QQ); EXPANSION: d. Amplia MRI CRT-D DF1 (Product No. DTMB1D1) Implantable devices that automatically detect and treat episodes of ventricular fibrillation, ventricular tachycardia, fast ventricular tachycardia, and bradyarrhythmia. Some devices can also provide resynchronization therapy, including sequential biventricular pacing (CRT-D devices).
Possible prevention of high and low voltage therapy in Medtronic Implantable Cardioverter Defibrillators (ICDs) and Cardiac Resynchronization Therapy Defibrillator (CRT-D).
a. Product No. DTMB1D4: UDI 00643169543430 (Serial No. RPJ201956H, RPJ202805H) (EXPANSION: Serial No. RPJ201660H, RPJ201661H, RPJ201972H, RPJ202145H, RPJ202821H, RPJ203208H, RPJ203209H, RPJ203826H); b. Product No. DTMB1Q1: UDI 00643169705784 (Serial No. RPU201108H) (EXPANSION: Serial No. RPU201289H, RPU201290H, RPU201291H, RPU201292H, RPU201293H, RPU201295H, RPU201296H, RPU201297H, RPU201298H, RPU201299H, RPU201300H, RPU201301H, RPU201302H, RPU201303H, RPU201305H, RPU201306H, RPU201287H, RPU201288H, RPU201619H, RPU201621H, RPU201635H, RPU201304H); c. Product No. DTMB1QQ: UDI 00643169929647 (Serial No. RPE219331H, RPE218183H), 00643169543386 (Serial No. RPE201417H, RPE204789H, RPE206207H, RPE207850H, RPE209095H, RPE212027H) (EXPANSION: Serial No. RPE215624H, RPE217014H, RPE200352H, RPE200394H, RPE201115H, RPE201328H, RPE202133H, RPE202941H, RPE203460H, RPE203771H, RPE203998H, RPE204209H, RPE204790H, RPE204791H, RPE204792H, RPE205432H, RPE206879H, RPE206886H, RPE208041H, RPE208241H, RPE208355H, RPE208369H, RPE208613H, RPE209037H, RPE209093H, RPE209135H, RPE209190H, RPE209194H, RPE209553H, RPE210227H, RPE210228H, RPE210672H, RPE210673H, RPE210734H, RPE210841H, RPE210844H, RPE210869H, RPE210870H, RPE210874H, RPE210875H, RPE211011H, RPE211012H, RPE211731H, RPE211732H, RPE211734H, RPE211736H, RPE211820H, RPE211858H, RPE211859H, RPE213564H, RPE214135H, RPE214544H, RPE214545H, RPE214546H, RPE215260H, RPE215628H, RPE216247H, RPE217013H, RPE217332H, RPE217335H, RPE217399H, RPE217443H, RPE217444H, RPE217446H, RPE217850H, RPE218146H, RPE218307H, RPE218308H, RPE219117H, RPE210877H, RPE215451H, RPE215625H, RPE215627H, RPE217445H, RPE217849H, RPE218148H, RPE215626H); EXPANSION: d. Product No. DTMB1D1: UDI 00643169705791 (Serial No. RPV200926H, RPV201075H, RPV201757H, RPV201758H)
US Nationwide Distribution.
951 devices total