v|tome|x L Series non-destructive testing cabinet x-ray systems

Recall: Z-0442-2021 · Reported November 25, 2020

Enforcement

Recall Number
Z-0442-2021
Event ID
86620
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Ge Inspection Technologies Llc
Voluntary / Mandated
FDA Mandated
Initial Notification
Letter
Report Date
November 25, 2020
Initiation Date
September 29, 2020
Classification Date
November 13, 2020
Termination Date
May 2, 2023
Address
721 Visions Dr, N/A, Skaneateles Falls, NY, 13153-5314, United States

Description

v|tome|x L Series non-destructive testing cabinet x-ray systems

Reason

It was discovered during testing of the v/tome/x L450 system s/n PA1790, that the pre-warning signals does not provide "Audible and visible warning signals within the cabinet" if the "warm up" mode was not completed after initializing the system when first turned on.

Code Info

v/tome/x L Series (L240, L300 or L450)

Distribution

USA Canada

Quantity

N/A