FDA Enforcement Class II Terminated

The Aeroneb Professional Nebulizer System is a portable medical device for multiple patient use that is intended to aerosolize physician-prescribed solutions for inhalation to patients on and off ventilation or other positive pressure breathing assistance. The Aeroneb Professional Nebulizer System is suitable for use in adult and pediatric patients. The Aeroneb Solo Nebulizer System is an iteration of the Aeroneb Professional Nebulizer System which is single patient use. The FRIWO AC/DC adapter is a component of the Aerogen Nebulizer systems which is used to power the Pro and Pro X controllers.

Recall: Z-0121-2015 · Reported October 29, 2014

Enforcement

Recall Number
Z-0121-2015
Event ID
69236
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
Aerogen Ltd.
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
Two or more of the following: Email, Fax, Letter, Press Release, Telephone, Visit
Report Date
October 29, 2014
Initiation Date
September 2, 2014
Classification Date
October 23, 2014
Termination Date
April 25, 2016
Address
Galway Business Park, Dangan, Galway, N/A, Ireland

Description

The Aeroneb Professional Nebulizer System is a portable medical device for multiple patient use that is intended to aerosolize physician-prescribed solutions for inhalation to patients on and off ventilation or other positive pressure breathing assistance. The Aeroneb Professional Nebulizer System is suitable for use in adult and pediatric patients. The Aeroneb Solo Nebulizer System is an iteration of the Aeroneb Professional Nebulizer System which is single patient use. The FRIWO AC/DC adapter is a component of the Aerogen Nebulizer systems which is used to power the Pro and Pro X controllers.

Reason

Aerogen has received a small number of complaints in relation to the main power adapter manufactured by FRIWO GmbH and used in the Aeroneb Solo and Pro Nebuliser systems. The complaints received identified that the power adapter cover had broken and dislodged from the body of the adapter prior to use.

Code Info

FRIWO AC/DC Adapter Model Number: GPP10; The FRIWO AC/DC Adapter is supplied with the following Aeroneb Nebulizer systems and their respective model numbers: 1) Model Number: AG-UC1000-NE; Lot Numbers: 9263140718116 , 9263140718137 , 9263140730049; 2) Model Number: AG-UC1000-UK; Lot Numbers: 9235140718022 , 9235140718093 , 9235140718154; 3) Model Number: AG-UC1500-NE; Lot Numbers: 9264140627057 , 9264140627100 , 9264140721112 , 9264140724100; 4) Model Number: AG-UC1500-SC; Lot Numbers: 9277140721040; 5) Model Number: AG-UC1500-SE; Lot Numbers: 9276140731046

Distribution

Worldwide Distribution-USA (nationwide) including the states of CA, GA, IL, MS, NC, and TX, and the countries of Australia, Belgium, Canada, China, Czech Republic, Denmark, Egypt, Finland, France, Germany, Hungary, India, Ireland, Israel, Italy, Kuwait, Libya, Malaysia, Netherlands, Norway, Poland, Qatar, Russia, South Korea, Singapore, Sweden, Switzerland, Thailand, Turkey, United Arab Emirates, United Kingdom, and Vietnam.

Quantity

323 power adapters