FDA Enforcement Class II Terminated

Centricity Cardio Imaging 5.0 is a software only Picture Archiving and Communication System (PACS). Product Usage: It will be sold as a software only device to operate on general purpose computing hardware. Centricity Cardio Imaging receives medical images and other information from various data sources. Information can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations. Centricity Cardio Imaging is intended to assist trained professionals in the viewing, analysis and diagnostic interpretation of images and other information for the diagnosis and treatment of cardiac and vascular disease. These trained professionals include but are not limited to physicians, cardiologists, radiologists, nurses, medical technicians and assistants. Centricity Cardio Imaging is not intended for use in the patient vicinity.

Recall: Z-0034-2014 · Reported October 30, 2013

Enforcement

Recall Number
Z-0034-2014
Event ID
64787
Classification
Class II
Status
Terminated
Product Type
Devices
Firm
GE Healthcare It
Voluntary / Mandated
Voluntary: Firm initiated
Initial Notification
Letter
Report Date
October 30, 2013
Initiation Date
October 2, 2012
Classification Date
October 21, 2013
Termination Date
May 16, 2016
Address
540 W Northwest Hwy, N/A, Barrington, IL, 60010-3051, United States

Description

Centricity Cardio Imaging 5.0 is a software only Picture Archiving and Communication System (PACS). Product Usage: It will be sold as a software only device to operate on general purpose computing hardware. Centricity Cardio Imaging receives medical images and other information from various data sources. Information can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations. Centricity Cardio Imaging is intended to assist trained professionals in the viewing, analysis and diagnostic interpretation of images and other information for the diagnosis and treatment of cardiac and vascular disease. These trained professionals include but are not limited to physicians, cardiologists, radiologists, nurses, medical technicians and assistants. Centricity Cardio Imaging is not intended for use in the patient vicinity.

Reason

GE Healthcare is aware of a potential safety risk where an image labeling situation exists in the Image Viewer software of the Centricity Cardio Imaging product, version 5.0 SP1. Multiple studies may be displayed side by side by selecting "Compare Study" from the Study List, or by opening prior studies in the Patient Folder. In these cases, the Viewer differentiates the studies wityh a label (Curr

Code Info

Software Version: 5.0

Distribution

USA Nationwide Distribution in the state of OK

Quantity

1 unit