Product Code: NST FDA class 2 21 CFR 866.5660

Autoantibodies, Acetylcholine Receptor, Acetylcholine Blocking And Non-Blocking

Immunology

The Acetylcholine Receptor Autoantibody (Blocking and Non-Blocking) device is an immunoassay used as an aid in the diagnosis of myasthenia gravis, an autoimmune disease characterized by exercise-induced muscle weakness. The assay detects autoantibodies in serum that interfere with the binding of acetylcholine at the neuromuscular junction, including both blocking and non-blocking antibody types. It is an FDA Class 2 device regulated under 21 CFR 866.5660 in the Immunology specialty, with product code NST, requiring 510(k) clearance. Third-party review is available. It is not an implant and does not provide life-sustaining support.

510(k)s
4
FEI Numbers
4
Registration Numbers
4
Unique Applicants
3
Years Active
5

Research product code NST in seconds

The Research Assistant summarizes clearances, adverse event trends and regulation context for a product code — and cites every record.

Free to try · every answer cites its records

Basic Information

Product Code
NST
Device Class
FDA class 2
Regulation Number
866.5660
Medical Specialty
Immunology
Review Panel
IM
Submission Type
1

Device Characteristics

GMP Exempt
Implant
Life Sustain/Support
Third Party
Summary Malfunction Reporting

Definition

THE DEVICE IS AN IMMUNOASSAY INDICATED AS AN AID IN THE DIAGNOSIS OF MYASTHENIA GRAVIS, AN AUTOIMMUNE DISEASE CHARACTERIZED BY EXERCISE-INDUCED MUSCLE WEAKNESS TEMPORARILY RELIEVED BY CESSATION OF EXERCISE. AUTOANTIBODY, WHEN PRESENT IN SERUM, INTERFERES WITH THE BINDING OF ACETYLCHOLINE, A NEURAL TRANSMITTER AT THE JUNCTION OF NERVES WITH MUSCLES. AUTOANTIBODY CAN ALSO BIND TO OTHER PORTIONS OF THE ACETYLCHOLINE RECEPTOR WITHOUT INTERFERING WITH ACETYLCHOLINE BINDING. PRESENCE OF AUTOANTIBODY ALONG WITH CLINICAL SIGNS AND SYMPTOMS ARE USUALLY HIGHLY SUGGESTIVE OF MYASTHENIA GRAVIS. ACETYLCHOLINE RECEPTOR AUTOANTIBODY CAN ALSO OCCUR IN THE PRESENCE OF AUTOANTIBODIES TO OTHER BODY SUBSTANCES.

510(k) Clearance History

Loading...

Related 510(k) Clearances

This FDA classification is associated with 4 510(k) clearances via K numbers.

K Number Device Name
K091468 IVD TECHNOLOGIES ACHRAB TEST KIT
K080523 KRONUS BLOCKING ACETYLCHOLINE RECEPTOR AUTOANTIBODY (ACHRAB) RIA ASSAY KIT
K051144 ACETYLCHOLINE RECEPTOR AB (ARAB)RRA
K042248 KRONUS, INC.'S ACETYLCHOLINE RECEPTOR ANTIBODY (ACHRAB) ASSAY KIT

FEI Numbers

This FDA classification entry is associated with 4 FEI numbers. Click on an entry to view related FDA registrations.

Registration Numbers

This FDA classification entry is associated with 4 registration numbers. Click on an entry to view related FDA registrations.