FDA Adverse Event Injury Summary report: N

MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT

MDR report key: 9995521 · Received April 24, 2020

Report

Report Number
2210968-2020-03446
Event Type
Injury
Date Received
April 24, 2020
Report Date
April 3, 2020
Manufacturer
ETHICON INC.
Product Code
GAN
PMA / PMN Number
K960653
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCTS (PDS II SUTURE, MONOCRYL SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCTS (PDS II SUTURE, MONOCRYL SUTURE) USED IN THIS PROCEDURE? WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. PATIENT DEMOGRAPHICS. CITATION: THER ADV UROL 2018, VOL. 10(11) 351¿355; DOI: 10.1177/1756287218790370. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: OUTCOMES OF ADULT URETHROPLASTY WITH COMMERCIALLY AVAILABLE ACELLULAR MATRIX" AUTHOR(S): AMY MARCIA PEARLMAN, VAIDEHI MUJUMDAR, KARA ELIZABETH MCABEE AND RYAN PATRICK TERLECKI. CITATION: THER ADV UROL 2018, VOL. 10(11) 351¿355; DOI: 10.1177/1756287218790370. THE GOAL OF THE PRESENT STUDY IS TO ASSESS SAFETY AND FEASIBILITY OF SUBSTITUTION URETHROPLASTY USING MATRISTEM GRAFT. A TOTAL OF 8 PATIENTS (MEN AGE OF 52 YEARS [33-72 YEARS]) UNDERWENT URETHRAL RECONSTRUCTION WITH EXTRACELLULAR MATRICE (ECM). IN THE PROCEDURE, GRAFTING WAS PERFORMED WITH EITHER ECM ALONE OR IN COMBINATION WITH BMG. 5-0 POLYDIOXANONE (PDS) (ETHICON, INC., SOMERVILLE, NEW JERSEY), 5-0 POLIGLECAPRONE 25 (MONOCRYL) (ETHICON, INC., SOMERVILLE, NEW JERSEY), OR POLYGLACTIN 10 (VICRYL) (ETHICON, INC., SOMERVILLE, NEW JERSEY) SUTURE WAS USED TO APPROXIMATE GRAFT MATERIALS TO THE URETHRAL PLATE, TO OTHER GRAFT MATERIAL, OR TO THE SKIN, AS APPROPRIATE. OF THE PATIENTS COMPLETING SECOND-STAGE REPAIRS, ONE PATIENT HAD URETHROCUTANEOUS FISTULA REQUIRING EXCISION. OUR FINDINGS SUGGEST THAT COMMERCIALLY AVAILABLE ECM CAN BE SUCCESSFULLY USED FOR SUBSTITUTION URETHROPLASTY. IN STAGED REPAIRS, ECM APPEARS TO PERFORM SIMILARLY TO BMG, BUT PATIENTS WITH COMPLEX DISEASE REMAIN AT RISK OF SUBSEQUENT RECURRENCE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
461413 MONOCRYL POLIGLECAPRONE 25 SUTURE UNKNOWN PRODUCT SUTURE, ABSORBABLE, SYNTHETIC GAN ETHICON INC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention