PDS II POLYDIOXANONE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2020-03257
- Event Type
- Injury
- Date Received
- April 21, 2020
- Report Date
- March 27, 2020
- Manufacturer
- ETHICON INC.
- Product Code
- NEW
- PMA / PMN Number
- N18331
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. THE FOLLOWING ADDITIONAL INFORMATION WAS REQUESTED BUT UNAVAILABLE: WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER FOR EACH PATIENT? DOES THE SURGEON BELIEVE THAT ETHICON PRODUCT (PDS II SUTURE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (PDS II SUTURE) INVOLVED? PATIENT DEMOGRAPHICS? CITATION: SCIENTIFIC REPORTS; (2018) 8:12942; DOI:10.1038/S41598-018-31287-8. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: A COMBINATION OF SUBCUTICULAR SUTURE AND ENHANCED RECOVERY AFTER SURGERY REDUCES WOUND COMPLICATIONS IN PATIENTS UNDERGOING HEPATECTOMY FOR HEPATOCELLULAR CARCINOMA". AUTHORS: ZU-SHUN CHEN; SHAO-LIANG ZHU; LU-NAN QI; LE-QUN LI. CITATION: SCIENTIFIC REPORTS; (2018) 8:12942; DOI:10.1038/S41598-018-31287-8. THE AIMED OF THIS PROSPECTIVE STUDY WAS TO EXAMINE WHETHER USING SUBCUTICULAR SUTURES DURING INITIAL HEPATECTOMY FOR HEPATOCELLULAR CARCINOMA (HCC) IS ASSOCIATED WITH SHORTER POSTOPERATIVE LENGTH OF HOSPITAL STAY (PLOS) THAN USING STAPLES FOR PATIENT TREATED IN THE ENHANCED RECOVERY AFTER SURGERY (ERAS) APPROACH. BETWEEN JANUARY 2012 AND JULY 2017, A TOTAL OF 376 PATIENTS WERE RANDOMIZED TO RECEIVE EITHER SUBCUTICULAR SUTURES OR STAPLES DURING HEPATECTOMY. SUBCUTICULAR SUTURE GROUP (MALE=135, FEMALE=53; MEAN AGE=52.33 ± 11.29 YEARS; MEAN BMI=25.34 ± 5.25 KG/M^2) WHEREAS STAPLES GROUP (MALE=131, FEMALE=57; MEAN AGE=52.19 ± 10.95 YEARS; MEAN BMI=25.13 ± 5.51 KG/M^2). IN THE GROUP RECEIVING SUBCUTICULAR SUTURES, THE FASCIA WAS CLOSED USING INTERRUPTED SUTURES WITH 0 OR 1 ABSORBABLE MONOFILAMENT POLYDIOXANONE SUTURE (PDS II, ETHICON), AND THE SUBCUTANEOUS SPACE WAS IRRIGATED WITH SALINE WITHOUT ANTIBIOTICS. INTERRUPTED SUBCUTICULAR SUTURES WITH A 4-0 MONOFILAMENT ABSORBABLE POLYDIOXANONE SUTURE (PDS II, ETHICON) WAS ALSO USED. THE SUTURE INTERVAL WAS 15 ¿ 25 MM, AND SUTURE BITE LENGTH WAS 15-25 MM FROM THE EDGE OF THE SKIN TO PROVIDE TIGHT SKIN CLOSURE. REPORTED COMPLICATIONS INCLUDED WOUND INFECTION (N=8), WOUND SEPARATION (N=5); BLOOD LOSS (N=?) DURING SURGERY OF 400 ML OR LESS, IN WHICH 18 PATIENTS HAD INTRAOPERATIVE BLOOD TRANSFUSION. IN CONCLUSION, THE STUDY PROVIDES THE FIRST EVIDENCE THAT SUBCUTICULAR SUTURING MAY BE MORE EFFECTIVE THAN STAPLES FOR HCC PATIENTS UNDERGOING HEPATECTOMY WITHIN AN ERAS APPROACH."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 446440 | PDS II POLYDIOXANONE SUTURE UNKNOWN PRODUCT | SUTURE, SURGICAL, ABSORBABLE | NEW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |