FDA Adverse Event Malfunction Summary report: N

NEEDLE CLIPPING DEVICE SAFE CLIP

MDR report key: 9938152 · Received April 8, 2020

Report

Report Number
2243072-2020-00574
Event Type
Malfunction
Date Received
April 8, 2020
Date of Event
March 26, 2020
Report Date
March 27, 2020
Manufacturer
BECTON DICKINSON
Product Code
FMI
UDI-DI
00382903282357
PMA / PMN Number
K943683
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. THE MANUFACTURING LOCATION FOR THIS PRODUCT IS (B)(4). THIS SITE IS AN OEM MANUFACTURING SITE. THEREFORE, BD CORPORATE HEADQUARTERS IN (B)(4) HAS BEEN LISTED AND THE (B)(4) FDA REGISTRATION NUMBER HAS BEEN USED FOR THE MANUFACTURE REPORT NUMBER. MULTIPLE LOT NUMBERS: THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 7176531. MEDICAL DEVICE EXPIRATION DATE: N/A. DEVICE MANUFACTURE DATE: 2017-07-14. MEDICAL DEVICE LOT #: UNKNOWN. MEDICAL DEVICE EXPIRATION DATE: UNKNOWN. DEVICE MANUFACTURE DATE: UNKNOWN. MEDICAL DEVICE LOT #: 7176532. MEDICAL DEVICE EXPIRATION DATE: UNKNOWN. DEVICE MANUFACTURE DATE: UNKNOWN. INVESTIGATION SUMMARY: LEVEL A INVESTIGATION - COMPLAINT EVALUATION / COMPLAINT HISTORY CHECK FOR THE EVENT(S) THAT OCCURRED. SEVERITY: S_1__; OCCURRENCE: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 2ND RELATED COMPLAINT FOR NOT CLIPPING ON LOT # 7176531. UNABLE TO PERFORM COMPLAINT LOT HISTORY CHECK FOR NOT CLIPPING FOR UNKNOWN LOT NUMBER. INVESTIGATION SUMMARY: NO SAMPLES (INCLUDING PHOTOS) WERE RETURNED THEREFORE THE COMPLAINT COULD NOT BE CONFIRMED AND THE ROOT CAUSE IS UNDETERMINED. IF SAMPLES ARE RECEIVED IN THE FUTURE THE COMPLAINT WILL BE REOPENED FOR FURTHER INVESTIGATION. ACCORDING WITH THE DHR REVIEW INFORMATION, THE PROBLEM ¿NOT CLIPPING¿ HAS NO NHB ASSEMBLY PROCESS RELATION, ALL SAMPLES OF SAFE CLIP DISPOSABLE CUTTER (USA) PASSED FUNCTIONAL TEST (AQL C=0 AND AQL=1) AND VISUAL TEST (SAMPLE PLAN C=0 AND AQL=1). INVESTIGATION CONCLUSION: AS NO SAMPLES AND/OR PHOTO(S) WERE RECEIVED THE INVESTIGATION CONCLUDED: UNCONFIRMED: BD WAS NOT ABLE TO DUPLICATE OR CONFIRM THE CUSTOMER¿S INDICATED FAILURE AS NO SAMPLES OR PHOTOS WERE RETURNED. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS. ROOT CAUSE DESCRIPTION: ROOT CAUSE CANNOT BE DETERMINED AT THIS TIME AS THE ISSUE IS UNCONFIRMED AS NO SAMPLES OR PHOTOS WERE RETURNED. RATIONALE: BASED ON THE INVESTIGATION, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME.

Description of Event or Problem · 1

IT WAS REPORTED THAT NEEDLE CLIPPING DEVICE SAFE CLIP WAS JAMMED. THIS WAS DISCOVERED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO: 328235 BATCH NO: 7176531, UNKNOWN (REPORTED 7176532 WHICH IS NOT VALID FOR ANY BD PRODUCTS). IT WAS REPORTED THAT THE CLIPPERS ARE NOT CLIPPING THE NEEDLES.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
400062 NEEDLE CLIPPING DEVICE SAFE CLIP HYPODERMIC SINGLE LUMEN NEEDLE FMI BECTON DICKINSON 328235 SEE H.10 00382903282357

Patients

Seq Age Sex Outcome Treatment
1 Other