. 5.0MM TROCAR 210MM
Report
- Report Number
- 8030965-2020-02442
- Event Type
- Malfunction
- Date Received
- March 31, 2020
- Date of Event
- February 28, 2020
- Report Date
- March 4, 2020
- Manufacturer
- OBERDORF SYNTHES PRODUKTIONS GMBH
- Product Code
- FZX
- UDI-DI
- 07611819765665
- PMA / PMN Number
- EXEMPT
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
DEPUY SYNTHESE IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHESE OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHESE, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. B5: ADDITIONAL INFORMATION H3, H6: A PRODUCT INVESTIGATION WAS CONDUCTED. VISUAL INSPECTION: THE RECEIVED INSTRUMENTS HAS SHOWN THAT NO SIGNIFICANT TRACES OF USE ARE PRESENT ONLY THE CUTTING EDGES OF THE DRILL BIT ARE WORN. BY THE EVIDENCE THAT THE CUTTING EDGES OF THE DRILL BIT ARE WORN, WE CAN CONCLUDE THAT THE DAMAGE IS A RESULT OF THAT THE DRILL BIT INTERFERED WITH THE NAIL AS REPORTED. FUNCTIONAL TEST: A FUNCTIONAL TEST WITH THE RETURNED INSTRUMENTS WAS PERFORMED. ANOTHER NAIL (DEMO - NAIL) WAS AVAILABLE TO REPRODUCE THE COMPLAINED ISSUE. THE COMPLAINED MALFUNCTION OF "THE DRILL BIT INTERFERED WITH THE NAIL" COULD NOT BE REPLICATED. THE RETURNED INSTRUMENTS PASSED THE FUNCTIONAL TEST SUCCESSFULLY. THE DRILL SLEEVE AND AS WELL THE DRILL BIT MET THE NAIL HOLE AS INTENDED. NO INTERFERING COULD BE DETECTED. DRAWING/SPECIFICATION REVIEW: THE MANUFACTURING REVIEW SHOWS THAT THE PRODUCTION PROCEDURES WERE ACCORDING TO THE SPECIFICATIONS AND THERE WERE NO ISSUES THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. FAILURE IN MATERIAL OR PRODUCTION COULD NOT BE DETECTED. DIMENSIONAL INSPECTION: AS THIS INVESTIGATION IS FOCUSED IN THE FUNCTIONAL ISSUE AND THIS WAS COVERED THROUGH THE FUNCTIONAL TEST PERFORMED. THEREFORE, NO MEASUREMENTS OF THE FEATURES ARE REQUIRED. SUMMARY: THE COMPLAINT IS RATED AS UNCONFIRMED FOR THESE INSTRUMENTS BECAUSE THAT THERE IS NO ALLEGATION AGAINST OF THESE DEVICES. THE RETURNED INSTRUMENTS PASSED THE FUNCTIONAL TEST SUCCESSFULLY. THE DRILL SLEEVE AND AS WELL THE DRILL BIT MET THE NAIL HOLE AS INTENDED. NO INTERFERING COULD BE DETECTED. UNFORTUNATELY, WE ARE NOT ABLE TO DETERMINE THE EXACT CAUSE OF THIS COMPLAINT. BASED ON OUR INVESTIGATIONS, WE ONLY CAN ASSUME THAT POSSIBLY AN INSUFFICIENT CONNECTION, OR THAT THE MOUNTED CONSTRUCT ENCOUNTERED UNINTENDED TORSIONAL FORCES, SUCH AS EXCESSIVE FORCE APPLICATION DURING INSERTION, WHICH FINALLY CAUSED THE MALPOSITION OF THE INSERT HANDLE / AIMING ARM. IN THIS RELATION WE WOULD LIKE TO MENTION FOLLOWING IMPORTANT STATEMENT OF THE PFNA SURGICAL TECHNIQUE ¿DSEM-TRM-0714-0120-3_LR.¿: - CAREFULLY INSERT THE PFNA MANUALLY USING SLIGHT BIDIRECTIONAL TURNS OF THE INSERTION HANDLE AS FAR AS POSSIBLE INTO THE FEMORAL OPENING. IF THE PFNA CANNOT BE INSERTED, SELECT A SMALLER SIZE PFNA DIAMETER OR REAM THE MEDULLARY CAVITY TO A DIAMETER THAT IS AT LEAST 1 MM LARGER THAN THAT OF THE SELECTED NAIL. - ALWAYS ENSURE THAT THE CONNECTION BETWEEN PFNA, INSERTION HANDLE AND AIMING ARM IS GOOD, OTHERWISE DRILLING FOR DISTAL LOCKING MAY DAMAGE THE PFNA. DURING THE INVESTIGATION, NO PRODUCT DESIGN OR MANUFACTURING ISSUES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION; THEREFORE, FURTHER CORRECTIVE AND/OR PREVENTIVE ACTION IS NOT REQUIRED. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED AS NO PRODUCT RELATED ISSUE COULD BE DETECTED. H3, H4, H6: A DEVICE HISTORY RECORD (DHR) REVIEW WAS CONDUCTED: PART: 03.010.070 LOT: L674743 MANUFACTURING SITE: BETTLACH RELEASE TO WAREHOUSE DATE: 22 DEC 2017. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE LOT NUMBER, AND NO NON-CONFORMANCES WERE IDENTIFIED. H11 CORRECTED DATA: D11: CORRECTED CONCOMITANT DEVICES DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
PATIENT'S OUTCOME IS REPORTED AS STABLE. CONCOMITANT DEVICES REPORTED: CONNECT-SCR-CANN F/PFN+PFNA (PART# 357.029, LOT# 2223477, QUANTITY# 1); INSERT-HANDLE RADIOLUC F/PFNA (PART # 03.010.405, LOT # 7595885, QUANTITY 1), PROTECT SLEEVE 11/8 L188 (PART # 03.025.040, LOT # L561859, QUANTITY 1), DRILL BIT Ø4.2 CALIBER L340 3FLUTE F/03.0 (PART # 03.010.061, LOT # L810568, QUANTITY 1), DRILLSL 8/4.2 F/03.010.063 (PART # 03.010.065, LOT # L491756, QUANTITY 1), AIM-ARM 125° F/PFNA BLADE (PART # 03.010.406, LOT # L664518, QUANTITY 1), UNK - NAILS (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1).
THE DEVICE WAS RECEIVED, THE INVESTIGATION IS IN PROGRESS, NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2020, THE PATIENT UNDERWENT A SURGERY. DURING THE SURGERY, THE DRILL BIT INTERFERED WITH THE NAIL. THE SURGEON DRILLED A PILOT HOLE WITH A K-WIRE, AND HE COULD DRILL AND INSERT A SCREW. THE SURGEON DIDN¿T KNOW CONCRETE MALFUNCTION OF THE DEVICES. IT WAS NOT REPORTED HOW THE SURGERY WAS COMPLETED. THE SURGICAL DELAY WAS UNKNOWN. CONCOMITANT DEVICES REPORTED: CONNECT-SCR-CANN F/PFN+PFNA (PART# 357.029, LOT# 2223477, QUANTITY# 1) THIS COMPLAINT INVOLVES SEVEN (7) DEVICES. THIS IS REPORT 6 OF 7 FOR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 369253 | . 5.0MM TROCAR 210MM | GUIDE | FZX | OBERDORF SYNTHES PRODUKTIONS GMBH | L674743 | 07611819765665 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | AIM-ARM 125° F/PFNA BLADE| AIM-ARM 125° F/PFNA BLADE| CONNECT-SCR-CANN F/PFN+PFNA| CONNECT-SCR-CANN F/PFN+PFNA| DRILL BIT Ø4.2 CALIBR L340 3FLUTE F/03.0| DRILL BIT Ø4.2 CALIBR L340 3FLUTE F/03.0| DRILLSL 8/4.2 F/03.010.063| DRILLSL 8/4.2 F/03.010.063| INSERT-HANDLE RADIOLUC F/PFNA| INSERT-HANDLE RADIOLUC F/PFNA| PROTECT SLEEVE 11/8 L188| PROTECT SLEEVE 11/8 L188| TROCAR Ø4.2 F/03.010.065| UNK - NAILS| UNK - NAILS |