FDA Adverse Event Malfunction Summary report: N

X-RAY FILM MARKING TAPE

MDR report key: 98688 · Received June 17, 1997

Report

Report Number
MW4001921
Event Type
Malfunction
Date Received
June 17, 1997
Report Date
September 30, 1996
Manufacturer
SPECTRONICS, CORP.
Product Code
JAC
Product Problem
Yes
Report Source
Voluntary report
Reporter Location
AP, US
Reporter Occupation
OTHER

Narratives

Description of Event or Problem · 1

LABELS ARE USED TO MARK INDUSTRIAL RADIOGRAPHIC FILM USED WHEN PERFORMING X-RAY INSPECTIONS ON AIRCRAFT. THE LABELS MUST HAVE ALL IDENTIFYING INFO EMBOSSED, NORMALLY WITH A BALL-POINT PEN, IN THE GREY PUTTY CENTER OF THE TAPE. UPON EXPOSURE TO X-RAYS, THIN AREAS WHERE WRITING HAS BEEN MADE LEAVE AN IMAGE OF ALL IDENTIFYING INFO ON THE XRAY FILM. IN THIS CASE, THE PUTTY IN THE LABEL HAS BECOME SO DECOMPOSED THAT IT HAS TURNED FROM A GRAY PUTTY TO AN OFF-WHITE POWDER. RPTR'S EXPERIENCE IS THAT THIS CONDITION NORMALLY OCCURS DUE TO EITHER TIME SINCE MFR OR IMPROPER STORAGE AND RENDERS THE LABEL UNSERVICEABLE. VERY OLD PRODUCT. MFR DATE 6/82, 12/82.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 X-RAY FILM MARKING TAPE X-RAY FILM MARKING TAPE JAC SPECTRONICS, CORP. 314X - 175 *

Patients

Seq Age Sex Outcome Treatment
1 *