FDA Adverse Event Malfunction Summary report: N

SUPRAMID BLACK 4/0 (1.5) 75CM DS19

MDR report key: 9837256 · Received March 16, 2020

Report

Report Number
3003639970-2020-00130
Event Type
Malfunction
Date Received
March 16, 2020
Report Date
March 16, 2020
Manufacturer
B.BRAUN SURGICAL SA
Product Code
GAR
PMA / PMN Number
SEE H10
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
HU
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

PMA/510K: REPORTED DEVICE NOT MARKETED IN THE U.S., HOWEVER, SIMILAR DEVICES OR DEVICES THAT SHARE COMPONENTS, RAW MATERIALS, PROCESS METHODS OR OTHER TECHNOLOGICAL CHARACTERISTICS ARE REGISTERED WITHIN THE U.S. K990090. SAMPLES RECEIVED: THERE ARE NO SAMPLES AVAILABLE. ANALYSIS AND RESULTS: THERE ARE NO PREVIOUS COMPLAINTS OF THE SAME CODE-BATCH. WE MANUFACTURED AND DISTRIBUTED IN THE MARKET 2,088 UNITS OF THIS CODE-BATCH. THERE ARE NO UNITS IN OUR STOCK. WE HAVE NOT RECEIVED ANY SAMPLE FOR ANALYSIS. WITHOUT ANY SAMPLES WE CANNOT CARRY OUT AN ANALYSIS IN ORDER TO TAKE A DECISION. REVIEWED THE BATCH MANUFACTURING RECORD, THIS PRODUCT HAD A NORMAL PROCESS AND THE RESULTS DURING THE PROCESS FULFIL USP/EP AND B. BRAUN SURGICAL REQUIREMENTS. NEEDLE ATTACHMENT STRENGTH RESULTS ON SAMPLES DURING THE PROCESS WERE 0.96 KGF IN AVERAGE AND 0.64 KGF IN MINIMUM AND FULFILLED THE REQUIREMENTS OF THE EUROPEAN PHARMACOPOEIA (EP REQUIREMENTS: 0.46 KGF IN AVERAGE AND 0.23 KGF IN MINIMUM). FINAL CONCLUSION: WITHOUT SAMPLES WE ARE NOT IN POSITION OF STUDYING IF THE AFFECTED PRODUCT DOES NOT FULFIL THE SPECIFICATIONS. IN CONSEQUENCE, A PROPER ANALYSIS CANNOT BE DONE AND THE CASE IS NOT CONFIRMED DUE TO LACK OF EVIDENCE. NEVERTHELESS, WE TAKE NOTE OF THIS INCIDENCE AND IF ANY SAMPLE IS RECEIVED IN THE FUTURE, WE WILL RE-OPEN THE CASE AND ANALYZE IT. PLEASE NOTE THAT WHEN NO SAMPLES ARE RECEIVED OUR ANALYSIS IS VERY LIMITED. ACTIONS ON PRODUCT DISTRIBUTED OF THIS REFERENCE/BATCH: BASED ON THE CONCLUSION DERIVED FROM INVESTIGATION, IT IS NOT REQUIRED TO MAKE ACTIONS IN DISTRIBUTED PRODUCT. NO CORRECTIVE/PREVENTIVE ACTIONS NEEDED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THERE IS AN ISSUE WITH A NEEDLE DETACHMENT. THE REPORTER INDICATED THAT THE THREAD SPLIT FROM THE NEEDLE. ADDITIONAL INFORMATION IS NOT AVAILABLE. PATIENT INFORMATION IS NOT AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
298064 SUPRAMID BLACK 4/0 (1.5) 75CM DS19 OTHER SUTURE GAR B.BRAUN SURGICAL SA C0714208 618521V030

Patients

Seq Age Sex Outcome Treatment
1