INCLUSIVE TAPERED IMPLANT 4.2 MMD X 8 MML X 3.5 MMP
Report
- Report Number
- 3011649314-2020-00157
- Event Type
- Malfunction
- Date Received
- March 14, 2020
- Date of Event
- November 19, 2019
- Report Date
- January 28, 2021
- Manufacturer
- PRISMATIK DENTALCRAFT, INC.
- Product Code
- DZE
- PMA / PMN Number
- K121406
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TU
- Reporter Occupation
- 003
Narratives
H10: INVESTIGATION METHODS RESULTS CORRECTED TO REFLECT THE DEVICE WAS RETURNED, BUT DID NOT TRANSFER TO INVESTIGATOR.
THE DEVICE WAS RETURNED, BUT DID NOT TRANSFER TO THE INVESTIGATOR. HOWEVER, THE DEVICE INVESTIGATION HAS BEEN COMPLETED AND THE RESULTS ARE AS FOLLOWS: DHR RESULTS: THE DHR WAS REVIEWED AND THERE WAS NO EVIDENCE DISCOVERED TO INDICATE THAT A PRODUCT DEFECT OR NON-CONFORMITY CONTRIBUTED TO THE ISSUE. THE PART MET ALL THE CRITERIA CALLED FOR IN THE PRODUCTION ROUTER. STOCK PRODUCT REVIEWED RESULTS: THERE WAS NO STOCK PRODUCT FROM LOT# 6050698 AVAILABLE FOR REVIEW. INVESTIGATION METHODS/RESULTS: CUSTOMER DID NOT RETURN THE COMPLAINT PART FOR INVESTIGATION. ROOT CAUSE: PROBABLE CAUSES COULD BE THE LACK OF PRIMARY STABILITY AT THE OSTEOTOMY SITE DUE TO INSUFFICIENT BONE OR POOR BONE QUALITY; EITHER THE BONE WAS TOO SOFT OR THE OPERATOR ERRED IN CREATING AN OSTEOTOMY BIGGER THAN THE SIZE OF THE IMPLANT DIAMETER. IFU 3023579 REV 3.0 (INCLUSIVE DENTAL IMPLANT SYSTEM) CONTAINS THE FOLLOWING STATEMENT IN WARNING SECTION: "ABSOLUTE SUCCESS CANNOT BE GUARANTEED. FACTORS SUCH AS INFECTION, DISEASE AND INADEQUATE BONE QUALITY AND/OR QUANTITY CAN RESULT IN OSSEOINTEGRATION FAILURES FOLLOWING SURGERY OR INITIAL OSSEOINTEGRATION." THE IFU ALSO CONTAINS THE FOLLOWING STATEMENT IN PRECAUTION SECTION: "MINIMIZING TISSUE DAMAGE IS CRUCIAL TO SUCCESSFUL IMPLANT OSSEOINTEGRATION. IN PARTICULAR, CARE SHOULD BE TAKEN TO ELIMINATE SOURCES OF INFECTION, CONTAMINANTS, SURGICAL AND THERMAL TRAUMA. RISK OF OSSEOINTEGRATION FAILURE INCREASES AS TISSUE TRAUMA INCREASES. ALL DRILLING PROCEDURES SHOULD BE PERFORMED AT 2000 RPM OR LESS UNDER CONTINUAL AND COPIOUS IRRIGATION. ALL SURGICAL INSTRUMENTS USED MUST BE IN GOOD CONDITION AND SHOULD BE USED CAREFULLY TO AVOID DAMAGE TO IMPLANTS OR OTHER COMPONENTS. IMPLANTS SHOULD BE PLACED WITH SUFFICIENT STABILITY; HOWEVER, EXCESSIVE INSERTION TORQUE MAY RESULT IN IMPLANT FRACTURE, OR FRACTURE OR NECROSIS OF THE IMPLANT SITE. THE PROPER SURGICAL PROTOCOL SHOULD BE STRICTLY ADHERED TO.". PER THE REPORTED INFORMATION, THE PATIENT HAD TYPE III BONE QUALITY. IT HAS BEEN SHOWN THAT THE QUALITY AND QUANTITY OF BONE AVAILABLE AT THE IMPLANT SITE ARE VERY IMPORTANT PATIENT FACTORS, IN DETERMINING THE SUCCESS OF DENTAL IMPLANTS. IT IS DIFFICULT TO OBTAIN IMPLANT ANCHORAGE IN BONE THAT IS NOT VERY DENSE. TYPE III: THIN LAYER OF CORTICAL BONE SURROUNDING A CORE OF DENSE TRABECULAR BONE. THEREFORE, THE PATIENT'S BONE QUALITY MAY HAVE BEEN A FACTOR.
CORRECTION H10 NARRATIVE OMITTED FROM THE FOLLOW UP SUBMISSION. THIS IS THE 1ST OF 3 FAILED IMPLANTS REPORTED ON THE SAME PATIENT. REFERENCE THE FOLLOWING MANUFACTURER REPORTS FOR THE REMAINING IMPLANTS. 3011649314-2020-00158, 3011649314-2020-00159.
THIS MW IS SUBMITTED LATE DUE TO AN UNEXPECTEDLY HIGH VOLUME OF COMPLAINTS FROM THIS INTERNATIONAL DISTRIBUTOR ON 1-13-20. THE FDA WAS MADE AWARE OF THE HIGH VOLUME OF COMPLAINTS BY GLIDEWELL. EMAIL RESPONSE RECEIVED FROM THE FDA ON 2-5-20. THE DEVICE HAS NOT BEEN RETURNED. IF/WHEN THE DEVICE IS RETURNED AN INVESTIGATION WILL BE CARRIED OUT AND A SUPPLEMENT REPORT WILL BE SUBMITTED. THE PATIENT RACE AND ETHNICITY WERE NOT PROVIDED; HOWEVER, THE PATIENT'S NATIONALITY IS LISTED AS (B)(6). THIS IS THE FIRST OF THREE IMPLANT COMPLAINTS. SEE MANUFACTURER REPORT FOR THE REMAINING COMPLAINT. 3011649314-2020-00158, 3011649314-2020-00159.
IT WAS REPORTED THAT THE IMPLANT FAILED. THE PATIENT HAS BONE GRADE TYPE III. THERE IS NO MEDICAL OR DENTAL HISTORY PRIOR TO IMPLANT. THE PATIENT PRESENTED ON (B)(6)2019 FOR PRIMARY PROCEDURE ON TOOTH #30 (UNIVERSAL). ON (B)(6)2019 THE PATIENT PRESENTED FOR SECOND STAGE PROCEDURE. UPON EXAMINATION, THE PROVIDER NOTES A LACK OF PRIMARY STABILITY. IT WAS AT THAT TIME THE DEVICE WAS REMOVED. THE PROVIDER STATES THE PATIENT CURRENT STATUS AS "PATIENT IS FINE".
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 296258 | INCLUSIVE TAPERED IMPLANT 4.2 MMD X 8 MML X 3.5 MMP | INCLUSIVE TAPERED IMPLANT | DZE | PRISMATIK DENTALCRAFT, INC. | 70-1070-IMP0026 | 6050698 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 49 YR |